![Westermo 3623-077001 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/westermo/3623-077001/3623-077001_user-manual_960535028.webp)
Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068-2-1
EN 60068-2-2
EN 60068-2-14
Operational
-40 to +70°C (-40 to +158°F)
a
Storage and
transport
-55 to +85°C (-67 to +185°F)
Humidity
EN 60068-2-30
Operational
5-95% relative humidity
Storage and
transport
Altitude
Operational
3000 m
MTBF
IEC TR 62380
240,000 hours
Vibration
MIL STD 810,
M514.7 (sine)
Operational
5 to 10 Hz, 5.08 mm p-p
10 to 200 Hz, 2.0 g
20 sweep cycles in each axis, 0.9
octave/min
EN 60068-2-64
(random)
Operational,
endurance test
2.3 m/s
2
random, 5 to 2000 Hz, 3 x 4 h
Shock
b
EN 60068-2-27
Operational
20 m/s
2
, 11 ms, 3 x 6 shocks (half sine)
MIL STD 810,
M516.7
10 g, 11 ms, 3 x 6 shocks (saw tooth)
Weight
1750 gr
Degree of protection
EN 60529
Enclosure
IP66
c
Cooling
Convection
Pollution degree
EN 62368-1
PD2
Conformal coating
type
IPC-A-610
Electronic
modules
AR (Acrylic)
a
Refer to "Safety and Regulations" chapter regarding touch temperature
b
The power and Ethernet cables need to be fastened 200 mm or closer to the unit. The same recommendation
applies to the Antenna cables.
c
Provided all connectors are connected with IP66 cabling or fitted with protective caps (delivered with the unit)
and tightened to the specified torque
Table 11. Environmental and mechanical conditions
28
Ibex-RT-370 Series