![Westermo 3623-077001 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/westermo/3623-077001/3623-077001_user-manual_960535016.webp)
NOTE
The optical performance is very dependent on the cleanliness of the FO
fibers. Small dust particles on the fibers will noticeable decrease the
performance and need to be removed by appropriate cleaning devices.
3.4.3. Ethernet Ports
The product includes an Ethernet ports X2 which supports auto-negotiated 10 Mbit/s, 100
Mbit/s and 1000 Mbit/s operation. Automatic MDI/MDIX crossover is supported for
10BASE-T, 100BASE-T, 1000BASE-T operation.
Marking
Position
Direction
Description
X1/X2
1
In/Out
DA+
2
In/Out
DA-
3
In/Out
DB+
4
In/Out
DB-
5
In/Out
DD+
6
In/Out
DD-
7
In/Out
DC-
8
In/Out
DC+
Housing
Shield
Chassis of product (ground)
Table 8. M12 X-coded 8-pin female Ethernet connector according to IEC 61076-2-109
NOTE
If the Ethernet function is not used, the protective dust cap which is part
of the delivery must be closed to protect the interface from water or dust
ingress.
3.4.4. Antenna Ports
The antenna connectors are identified on the product with A1 to A4.
A1 to A3 are used for WLAN communication at 2.4 GHz/5 GHz. At least A1 must be
connected to an external WLAN antenna. The antenna configuration is made through the
software interface.
A4 is used for real-time scanning/monitoring of the occupied WLAN frequencies bands and
possible Radar interferences. A4 must be connected to an external WLAN antenna to
make use of the scanning/monitoring functions.
16
Ibex-RT-370 Series