NOTE
This product has no replaceable fuse and should be connected via an
external fuse for protection.
NOTE
External connector Binder 99-4222-00-04 (outer cable diameter 6 to 9.5
mm) or Binder 99-4222-14-04 (outer cable diameter 10 to 12 mm) shall
be used in order to fulfill the specified ingress protection code at the
power connector.
4.5. Cooling
This product uses convection cooling. Make sure that it is installed so that the ambient
temperature is within the specified temperature range, e.g. by avoiding obstruction of the
airflow around the product.
It is recommended to install the product in areas where the natural convection airflow is
not blocked and that there is enough spacing around the product.
Figure 8. Installation with reduced natural convection
airflow
Figure 9. Installation with natural convection airflow
When operating the product at high ambient temperatures, it is recommended to mount
the product to a metallic base plate to improve the heat dissipation. The base plate
increases the surface to spread the heat.
Ibex-RT-370 Series
21