WARNING - RADIO PRODUCTS
Observe the usage limitations of radio products at filling stations, in
chemical plants, in systems with explosives or potentially explosive
locations.

The product may not be used in airplanes. Exercise particular caution near
personal medical aids, such as pacemakers and hearing aids. Never
perform work on the antenna system during a thunderstorm.

To fulfill human safety, a minimum separation distance of 20 cm or more
should be maintained between the antenna of the product and personnel
during operation.

CAUTION - HOT SURFACE
Be aware that the surface of this product may become hot. When it is
operated at high temperatures, the external surface may exceed Touch
Temperature Limit according to the product's relevant electrical safety
standard.

This product complies with Touch Temperature Limits throughout its
operational temperature range.

CAUTION - CORROSIVE GASES
If the product is placed in a corrosive environment, it is important that all
unused connector sockets are protected with a suitable plug, in order to
avoid corrosion attacks on the gold plated connector pins.

CAUTION - CABLE TEMPERATURE RATING FOR FIELD
TERMINAL WIRES
There may be a requirement on the minimum temperature rating of the
cable to be connected to the field wiring terminals, see Interface
Specifications.

2.3. Care Recommendations

Follow the care recommendations below to maintain full operation of the product and to
fulfill the warranty obligations:

Ibex-RT-630 Series

7

Содержание 3623-075001

Страница 1: ...www westermo com Ibex RT 630 Series EN 50155 LTE and WLAN Router...

Страница 2: ...Product Description 12 3 1 Product Description 12 3 2 Available models 13 3 3 Hardware Overview 13 3 3 1 Frontside Overview 13 3 3 2 Front Side Label 14 3 3 3 Rear Side Label 14 3 3 4 Interface Ports...

Страница 3: ...7 Revision Notes 35 Ibex RT 630 Series 3...

Страница 4: ...ww westermo com 1 2 About This Guide This guide is intended for installation engineers and users of the Westermo products It includes information on safety and regulations a product description instal...

Страница 5: ...ardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides...

Страница 6: ...conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that...

Страница 7: ...emperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard This product complies with Touch Temperature Limits throughout its op...

Страница 8: ...ould not be kept unpowered for more than 30 days 2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed ove...

Страница 9: ...ect Spread UTRA for Mobile and portable UE radio and ancillary equipment ETSI EN 301 489 52 Electromagnetic Compatibility EMC standard for radio equipment and services Part 52 Specific conditions for...

Страница 10: ...ates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee...

Страница 11: ...oit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement NOTE This product contains the IC Certification numbers 9301A 103902DT50 WLA...

Страница 12: ...le in local LED status indicators and through SNMP WebGUI The Mobile Communication Gateway router is designed to withstand tough onboard environmental conditions and can be remotely managed using web...

Страница 13: ...V NA North America 72 110 VDC Table 2 List of available models 3 3 Hardware Overview 3 3 1 Frontside Overview DC OPR ERR X1 X2 1 4 2 3 5 6 7 No Description 1 SIM card slot 2 Gigabit Ethernet ports X1...

Страница 14: ...he data matrix is AAAAAAAAARR 1 VV SSSSSSSS YYWW AAAAAAAAA Article number RR Region code VV Product revision SSSSSSSS Serial number YY Manufacturing Year WW Manufacturing Week Table 4 Front side label...

Страница 15: ...ing point 5 Power Table 5 Interface ports view 3 4 Connector Information 3 4 1 Power Input Connection Marking Position Direction Description DC 1 DC Positive terminal 2 3 DC Negative terminal 4 Housin...

Страница 16: ...kets in slot 1 and or slot 2 with the contacts facing down Let chamfered corners align according markings on the drawer Put the SIM card drawer back into the unit ensuring that it fits into place and...

Страница 17: ...4 3 Ethernet Ports The product includes two Ethernet ports X1 and X2 which supports auto negotiated 10 Mbit s 100 Mbit s and 1000 Mbit s operation Automatic MDI MDIX crossover is supported for 10BASE...

Страница 18: ...with A1 to A6 QMA industrial standard connector is used A4 and A5 are used for LTE communication Both antennas ports must be used and connected to external LTE antennas A1 to A3 are used for WLAN comm...

Страница 19: ...igure 6 LED indicators LED Description DC Power status OPR Operation status ERR Error status X1 Ethernet status for X1 port X2 Ethernet status for X2 port Table 9 LED indicators NOTE Refer to manageme...

Страница 20: ...93 190 111 4 31 35 22 8 22 38 5 16 8 8 DC X2 X1 DC ERR X1 X2 OPR 3623 07500100001089 2012 Power 24VDC 0 6A Ibex RT 630 LV EU A1 A2 A3 A4 A5 A6 Figure 7 Dimensional drawing 20 Ibex RT 630 Series...

Страница 21: ...to ensure proper heat dissipation NOTE For outdoor installation consider additional protection against sun radiation dust and dirt to optimize ambient temperature range NOTE Unused connectors must be...

Страница 22: ...with a cross section of at least 4 mm2 shall be used The grounding wire is set below the rip lock washer The nut is fixed for good reliable grounding contact The tightening torque of the nut shall be...

Страница 23: ...rflow is not blocked and that there is enough spacing around the product Figure 9 Installation with reduced natural convection airflow Figure 10 Installation with natural convection airflow When opera...

Страница 24: ...rms Improve installation conditions or RF parameters in case of any temperature alarms 4 6 Replacement of Product Disconnect all cables and unscrew the product from the wall Mount the replacement prod...

Страница 25: ...mA2 at 110 VDC Startup currenta 2 x nominal current Polarity Reverse polarity protected Redundant power input No Conductor cross section flexible 0 5 mm AWG 20 Cable temperature rating 40 to 70 C Shi...

Страница 26: ...the far end side of the Ethernet cable shield itself is connected to protective earth SIM card SIM type Mini SIM 2FF Temperature rating Industrial grade Antenna WLAN A1 to A3 Connector QMA female Dire...

Страница 27: ...NOTICE Depending on the installation country there are frequency band restrictions and output power limitations Ibex RT 630 Series 27...

Страница 28: ...B41 B29 B30 B39 B41 B66 B12 B29 B30 B5 B14 B30 B66 B29 and B32 are for secondary component carrier only DL 2 CA DL intra band 2CA B1 B3 B5 B18 B19 B20 B21 B26 B2 B4 B5 B12 B13 B14 B17 B29 B30 B66 B3 B...

Страница 29: ...ion Receive LNA supply voltage Max 3 7 VDC DC voltage for active antenna LNA supply current Max 70 mA DC current for active antenna Cabling 50 Ohm coaxial cable and GNSS antenna required Conductive ch...

Страница 30: ...es on the antenna interfaces ensure that the far end side of the antenna cable and or the antenna itself is connected to protective earth NOTE External GNSS LNA is recommended to improve sensitivity 3...

Страница 31: ...e 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 AM 1kHz at 80 MHz to 6 GHz 30 V m PM 200 Hz square at 380 MHz to 385 MHz 30 V m PM 200 Hz square at 390 MHz to 395 MHz 3 V m PM 200 Hz s...

Страница 32: ...o 150 Hz 3 x 5 h Shockb EN 60068 2 27 Operational 100 m s2 30 ms 3 x 6 shocks half sine MIL STD 810 M516 7 10 g 11 ms 3 x 6 shocks saw tooth Weight 1650 gr Degree of protection EN 60529 Enclosure IP66...

Страница 33: ...D Electro Static Discharge ETSI European Telecommunications Standards Institute FCC Federal Communication Commission FLOSS Free Libre Open Source Software Galileo European Global Positioning System GN...

Страница 34: ...nith Satellite System RF Radio Frequency TNV Telephone Network Voltage SBAS Satellite Based Augmentation System SIM Subscriber Identity Module SN Serial Number SNMP Simple Network Management Protocol...

Страница 35: ...cy Approvals and Standards Compliance updated 3 3 2 Front Side Label callouts reversed order 3 5 Led Indicatiors illustration added 4 2 Factory Reset moved from old chapter 3 6 4 5 Cooling illustratio...

Страница 36: ...Westermo Metallverksgatan 6 SE 721 30 V ster s Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6623 22905 REV D 2021 10 Westermo Network Technologies AB Sweden...