5.2. Type Tests and Environmental Conditions
Environmental
phenomena
Basic
standard
Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
DC power port
± 2 kV, direct coupling
Ethernet ports
± 2 kV, capacitive coupling clamp
Antenna ports
Surge
EN 61000-4-5
DC power port
L-E: ± 1 kV, 12
Ω
, 9 µF, 1.2/50 µs
L-E: ± 2 kV, 42
Ω
, 0.5 µF, 1.2/50 µs
L-L: ± 1 kV, 12
Ω
, 9 µF, 1.2/50 µs
L-L: ± 2 kV, 42
Ω
, 0.5 µF, 1.2/50 µs
Ethernet ports
L-E: ± 1 kV, 2
Ω
, 18 µF, 1.2/50 µs
Antenna ports
Power frequency
magnetic field
EN 61000-4-8
Enclosure
300 A/m continues, DC, 16.7 Hz, 50 Hz,
60 Hz
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF
immunity
EN 61000-4-3
Enclosure
20 V/m, 80% AM (1kHz) at 80 MHz to 6
GHz
30 V/m, PM 200 Hz square at 380 MHz to
385 MHz
30 V/m, PM 200 Hz square at 390 MHz to
395 MHz
3 V/m, PM 200 Hz square at 104, 136, 165,
200, 260, 330, 430, 560, 715 ±1, 920 ±1
MHz
Conducted RF
immunity
EN 61000-4-6
DC power port
10 V, 80% AM (1 kHz) from 0.15 to 80
MHz
Ethernet ports
Antenna ports
Radiated RF emission
CISPR 16-2-3
Enclosure
Class B
FCC Part 15 B, Class B
Conducted RF
emission
CISPR 16-2-1
DC power port
Ibex-RT-630-LV: Class B
Ibex-RT-630-HV: Class A
Ethernet ports
Insulation resistance
EN 50155
Power port (DC)
to all other ports
> 100 MOhm
Dielectric strength
EN 50155
Power port (DC)
to all other ports
Ibex-RT-630-LV: 750 VDC, 60 s
Ibex-RT-630-HV: 2250 VDC, 60 s
Table 10. EMC and electrical conditions
Ibex-RT-630 Series