FAULTS TABLE
CODE DISPLAYED
FAULT
ACTION
E01
Failed ignition shutdown.
Press and hold down for at least 2 seconds.
E02
Shut down by safety thermostat.
Press and hold down for at least 2 seconds.
E03
Board configuration error
Call the Authorised Service Centre.
E04
Safety error due to ignition failure/frequent flame
loss.
Press and hold down for at least 2 seconds.
E05
Flow sensor failure.
Call the Authorised Service Centre.
E06
DHW sensor fault.
Call the Authorised Service Centre.
E07
Fumes NTC probe fault.
Press and hold down for at least 2 seconds.
E08
Error in the flame amplification circuit.
Call the Authorised Service Centre.
E09
Error in the gas valve safety circuit.
Call the Authorised Service Centre.
E10
No hydraulic pressure switch enable.
Check that the pressure in the system is correct; See the FILLING
THE SYSTEM section.
E22
Switching off due to power supply reductions.
Automatic reset at voltages in excess of 170V. If this fault
persists, call the Authorised Service Centre.
E25
No water safety trip (pump probably blocked).
Press and hold down for at least 2 seconds.
E26
Heating circuit overheated/ no water safety trip
(pump probably blocked).
If this fault persists, call the Authorised Service Centre.
E27
DHW probe incorrectly positioned.
Press and hold down for at least 2 seconds.
E35
Parasite flame (flame error).
If this fault persists, call the Authorised Service Centre.
E36
Fumes NTC probe fault.
Call the Authorised Service Centre.
E40 - E41
Shutdown due to probable obstruction of air/flue
duct or insufficient gas inlet pressure.
Press and hold down for at least 2 seconds.
E42
Flame loss (air/flue duct may be totally obstructed or
fan may be faulty).
Press and hold down for at least 2 seconds.
E43
Shutdown due to probable obstruction of air/flue
duct or insufficient gas inlet pressure.
Temporary fault. Automatic reset at voltages in excess of 185V or
press for at least 2 seconds.
E50
Shutdown due to fumes NTC probe tripping for
overheating.
Press and hold down for at least 2 seconds.
E55
Gas valve not electronically calibrated.
Call the Authorised Service Centre.
E62
Safety shutdown if the flame signal or fumes
temperature fail to stabilise
Press and hold down for at least 2 seconds.
E65
Safety shutdown if the air/flue duct obstruction test
fails frequently.
Press and hold down for at least 2 seconds.
E98
Electronic board parameters incorrectly configured. Call the Authorised Service Centre.
Flashing lights
Boiler operating at reduced power. Air/flue duct may
be obstructed or gas inlet pressure may be too low.
Temporarily eliminate the current heat request to reset the fault. If
this fault persists, call the Authorised Service Centre.
Flashing alternately
Scale alarm or incorrect position of NTC probe.
Call the Authorised Service Centre.
In case of a fault, the display backlighting flashes together with the error code.
If a fault code is displayed that is not included in the list or if a certain fault occurs frequently, contact the AUTHORISED
TECHNICAL SERVICE CENTRE.
8. ROUTINE MAINTENANCE INSTRUCTIONS
To keep the boiler efficient and safe, have it checked by the Authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
Содержание Quasar E
Страница 21: ...21 7113156 01 1 05 13 ...
Страница 41: ...41 7113156 01 1 05 13 ...
Страница 61: ...61 7113156 01 1 05 13 ...
Страница 81: ...81 7113156 01 1 05 13 ...
Страница 101: ...101 7113156 01 1 05 13 ...
Страница 121: ...121 7113156 01 1 05 13 ...
Страница 141: ...141 7113156 01 1 05 13 ...
Страница 142: ...7113156 01 1 05 13 142 S E C T I O N A ...
Страница 144: ...7113156 01 1 05 13 144 S E C T I O N A ...
Страница 146: ...7113156 01 1 05 13 146 S E C T I O N B ...
Страница 148: ...7113156 01 1 05 13 148 S E C T I O N B ...
Страница 150: ...7113156 01 1 05 13 150 S E C T I O N C ...
Страница 151: ...151 S E C T I O N C 7113156 01 1 05 13 ...
Страница 152: ...7113156 01 1 05 13 152 S E C T I O N D ...
Страница 154: ...7113156 01 1 05 13 154 S E C T I O N E ...