Item #
Section
6
Downlink
Gain [dB]
Displays downlink gain in the 700 MHz range
ALC Atten [dB]
Displays attenuation value by ALC
Atten [dB]
Displays attenuation value controlled by down link
AGC Atten [dB]
Displays attenuation value controlled by AGC
AGC
Control Auto Level Control Function On/Off
AGC Level [dBm]
Sets the unit’s maximum ALC output value
HPA
Down link HPA On/Off
Item #
Section
7
Gain (dB)
Displays status of the uplink gain
ALC Atten [dB]
Displays attenuation value controlled by ALC
Atten [dB]
Sets the attenuation value
AGC Atten [dB]
Displays attenuation value controlled by AGC
AGC
Control Auto Gain Control Function On/Off
AGC Level [dBm]
Sets the unit’s maximum AGC output value
HPA
Uplink HPA On/Off
Item #
Section
8
Isolation
Isolation Value
When power is on, an isolation check is performed
and the values display.
Isolation
The isolation check can be performed with the RF on
or off.
Isolation Recheck
The isolation check can be performed with the RF on
or off.
Note
: Neither the isolation check nor recheck will indicate a change in power
levels if the unit’s own power has been switched off.