Tub tilts fully, ice cubes
are
discharged,
but
trough no longer returns
into original position
1. Defrosting thermostat
does not transfer voltage
to tilting motor
2. Tilting motor faulty
1. Readjust defrosting thermostat
(set to +17°C) or replace
2. Replace tilting motor 2
Tub tilts fully (contact
with
limit
switch
is
made) but immediately
returns to original posi-
tion
Mechanical or electrical
fault at hot gas valve
Replace hot gas valve
Ice cube maker not
working despite produc-
tion switched on
1. Machine receives no
voltage from power supply
2. Storage container is full
(storage container ther-
mostat has switched off)
3.
Storage
container
thermostat switches off
before storage container
is full.
4. Ambient temperature
too low
5. Production switch of the
ice cube maker is faulty
6. Production switch in
wrong position (“Service”
or “Produktion aus/off”).
1. Check socket
2. The ice cube maker will automati-
cally continue producing ice once a
sufficient quantity of ice has been
removed from the storage container.
3. Readjust storage container ther-
mostat, or replace if necessary
4.Increase ambient temperature, or
relocated device if necessary
5. Replace production switch
6. Set production switch to position
“Produktion ein/on”.
Ice cubes stick to each
other during the ice-
making process
1. Ice thickness motor
switches too late
2. Leak(s) in the cooling
system (ice maker has in-
sufficient refrigerant)
1. Readjust ice thickness motor(see
also capitel 6.3)
2. Locate leak(s), rectify and top up
refrigerant
Kippmotor