SELF RETRACTING LIFELINES WITH 
LEADING EDGE CAPABILITY

Complies with the ANSI Z359.14 standard and 
OSHA 29 CFR 1910 and 1926 regulations.

USER INSTRUCTIONS

Werner Co. Fall Protection 

724-588-2000

93 Werner Rd. 

888-523-3371 toll free

Greenville, PA 16125 

888-456-8458 fax 

         WARNING!   

Compliant fall protection equipment must only be used as it was designed. Users MUST read 
and follow all user instructions provided with the product.  Before using a fall arrest system, 
users must be trained in the safe use of the system, as required by OSHA 29 CFR 1910.30 and 
1926.503, or local safety regulations.  

Misuse or failure to heed these warnings and 

instructions may result in injury or even death. 

WORK SAFE! WORK SMART!  

IF YOU HAVE ANY QUESTIONS ABOUT THE PROPER USE OF THE EQUIPMENT, SEE YOUR 
SUPERVISOR, USER INSTRUCTIONS, OR CONTACT WERNER CO. FOR MORE INFORMATION.

 This manual applies to SRL model numbers R410020LE, R410030LE and R410065LE.

Содержание MAX PATROL R410020LE

Страница 1: ... read and follow all user instructions provided with the product Before using a fall arrest system users must be trained in the safe use of the system as required by OSHA 29 CFR 1910 30 and 1926 503 or local safety regulations Misuse or failure to heed these warnings and instructions may result in injury or even death WORK SAFE WORK SMART IF YOU HAVE ANY QUESTIONS ABOUT THE PROPER USE OF THE EQUIP...

Страница 2: ...s sharp edges or abrasive surfaces Contact with these elements may cause equipment failure personal injury or death 7 Do not expose SRL LE to chemicals or harsh solutions which may have a harmful effect 8 Personal fall arrest systems including SRL LE must be inspected prior to each use for wear damage and other deterioration Defective components must be immediately removed from service in accordan...

Страница 3: ...emperatures may cause damage to the SRL LE s When working with such chemicals frequent inspection of this equipment must be performed Contact Werner Co with any questions concerning the use of the SRL LE around chemical hazards 5 EXTREME TEMPERATURE SRL LE s are designed to be used in temperatures ranging from 40 F to 130 F 40 C to 54 C Protection should be provided for SRL LE s when used near wel...

Страница 4: ...s from being engaged to certain objects unless two requirements are met snap hook must be a locking type and must be designed for making such a connection Under OSHA designed for means that the manufacturer of the snap hook specifically designed the snap hook to be used to connect to the equipment in question The following connections must be avoided because they can result in rollout when a non l...

Страница 5: ...he required clearance includes Free Fall and Swing Fall Distance Harness Stretch Deceleration Distance and Safety Factor CLEARANCE REQUIREMENT WITH OFFSET AND SETBACK DISTANCE FOR LEADING EDGE APPLICATIONS FOR R410065LE SETBACK DISTANCE OFFSET DISTANCE 2 Foot 0 6m 4 Foot 1 2m 6 Foot 1 8m 8 Foot 2 4m 10 FOOT 3 0m 12 Foot 3 7m 14 Foot 4 3m 16 Foot 4 9m 18 Foot 5 5m 20 Foot 6 1m 0 Foot 0m 17 5 ft 5 4...

Страница 6: ... ft 0 6 m 3 ft 0 9 m 2 ft 0 6 m 1 ft 0 3 m 0 ft 0 m 1 ft 0 6 m 2 ft 0 6 m 3 ft 0 9 m 4 ft 1 2 m 5 ft 1 5 m 4 ft 1 2 m 5 ft 1 5 m 6 f t 1 8 m 8 f t 2 4 m 1 0 f t 3 0 m 1 2 f t 3 7 m 1 4 f t 4 3 m 1 6 f t 4 9 m 5 ft 1 5 m 7 f t 2 1 m 9 f t 2 7 m 1 1 f t 3 4 m 1 3 f t 4 0 m 1 5 f t 4 6 m 1 7 f t 5 2 m 1 9 f t 5 8 m 21 ft 6 4 m 1 8 f t 5 5 m 2 0 f t 6 1 m 2 2 f t 6 7 m 2 0 f t 6 1 m 2 0 m m m m 1 8 f ...

Страница 7: ... 2 1 m 1 1 1 1 m 1 2 3 f t 7 0 m 2 3 2 3 3 2 2 2 2 1 ft 0 3 m 0 ft 0 m 1 ft 0 3 m 2 ft 0 6 m 3 ft 0 9 m 4 ft 1 2 m 5 ft 5 5 m 5 f 1 5 4 ft 1 2 m 3 ft 0 9 m 2 ft 0 6 m D ring Height Above D ring Below D ring Offset Offset Centerline EXAMPLE With the R410065LE anchored 4 feet above the users D ring and the user works 2 feet away offset from directly overhead centerline the required clearance is 7 fe...

Страница 8: ...on Self Retracting Lifeline Maximum Arrest Distance per ANSI Z359 14 Class A 2 ft 0 6 m Safety Factor 2 ft 0 6 m 1 ft 0 31 m Harness Stretch To Worker s Back D Ring 5 ft 1 5 m Total Estimated Distance 10 ft 3 0 m Estimated Clearance Required 5 ft 1 5 m Working Level Lower Level or Obstruction Self Retracting Lifeline Maximum Arrest Distance per ANSI Z359 14 Class B 4 5 ft 1 4 m Safety Factor 2 ft ...

Страница 9: ... including SRL LE s must be inspected prior to each use for wear damage and other deterioration Defective components must be immediately removed from service in accordance with the requirements of OSHA 29 CFR 1910 140 and 1926 502 and or applicable local governmental and jurisdictional standards Standards and Regulations Free Fall Limit Maximum Arrest Force Average Arrest Force Minimum Setback Dis...

Страница 10: ...p hooks and carabiners on product must be able to self close and lock All hardware must be free of cracks sharp edges deformation corrosion or any evidence of defect All components of the fall arrest system must be inspected See User Instructions supplied with each product CLEANING MAINTENANCE AND STORAGE CLEANING Cleaning and maintenance may be performed by the user The SRL LE may be wiped down w...

Страница 11: ...stance Clearance Requirement when Falling over Edge Capacity ANSI Z359 14 SRD LE 6 1 8 m 1800 lbs 8 kN 900 lbs 4 kN 2 0 6 m 17 5 1 m 130 310 lbs 59 141 kg OSHA 29 CFR 1910 140 1926 502 6 1 8 m 1800 lbs 8 kN N A 2 0 6 m 17 5 1 m 310 lbs 141 kg Tested and approved for leading edge use over steel beam B Deck and precast concrete Model R410030LE Self Retracting Lifeline with Leading Edge Capability Ma...

Страница 12: ...PN115849 01 2018 Werner Co Rev B 6 18 Werner Co Fall Protection 93 Werner Rd Greenville PA 16125 724 588 2000 888 523 3371 toll free 888 456 8458 fax ...