5
CLEARANCE REQUIREMENTS
C
LEARANCE
R
EQUIREMENT
WITH
O
FFSET
AND
S
ETBACK
D
ISTANCE
FOR
L
EADING
E
DGE
A
PPLICATIONS
FOR
R410020LE
AND
R410030LE
S
ETBACK
D
ISTANCE
O
FFSET
D
ISTANCE
2 Foot
(0.6m)
4 Foot
(1.2m)
6 Foot
(1.8m)
8 Foot
(2.4m)
10 F
OOT
(3.0m)
12 Foot
(3.7m)
14 Foot
(4.3m)
16 Foot
(4.9m)
18 Foot
(5.5m)
20 Foot+
(6.1m)+
0 Foot (0m)
17.0 ft
(5.2m)
17.0 ft
(5.2m)
17.0 ft
(5.2m)
17.0 ft
(5.2m)
17.0 ft
(5.2m)
17.0 ft
(5.2m)
17.0 ft
(5.2m)
17.0 ft
(5.2m)
17.0 ft
(5.2m)
17.0 ft
(5.2m)
2 Foot (0.6m)
17.8 ft
(5.4m)
17.5 ft
(5.3m)
17.3 ft
(5.3m)
17.2 ft
(5.2m)
17.2 ft
(5.2m)
17.2 ft
(5.2m)
17.1 ft
(5.2m)
17.1 ft
(5.2m)
17.1 ft
(5.2m)
17.1 ft
(5.2m)
4 Foot (1.2m)
19.5 ft
(5.9m)
18.7 ft
(5.7m)
18.2 ft
(5.5m)
17.9 ft
(5.5m)
17.8 ft
(5.4m)
17.6 ft
(5.4m)
17.6 ft
(5.4m)
17.5 ft
(5.3m)
17.4 ft
(5.3m)
17.4 ft
(5.3m)
6 Foot (1.8m)
20.2 ft
(6.2m)
19.5 ft
(5.9m)
19.0 ft
(5.8m)
18.7 ft
(5.7m)
18.4 ft
(5.6m)
18.2 ft
(5.5m)
18.1 ft
(5.5m)
18.0 ft
(5.5m)
17.9 ft
(5.5m)
8 Foot (2.4m)
21.0 ft
(6.4m)
20.3 ft
(6.2m)
19.8 ft
(6.0m)
19.4 ft
(5.9m)
19.1 ft
(5.8m)
18.9 ft
(5.8m)
18.7 ft
(5.7m)
18.5 ft
(5.6m)
10 Foot (3.0m)
20.6 ft
(6.3m)
20.2 ft
(6.2m)
19.9 ft
(6.1m)
19.9 ft
(6.0m)
19.4 ft
(5.9m)
DO NOT
USE
E
XAMPLE
:
With the SRL-LE anchor set back 10 feet from the edge, the user can work up to 8 feet
(2.4m) offset along the leading edge. The required clearance is 19.8 feet (6.0 m) from the working
level to the nearest obstruction below.
The required clearance includes; Free Fall and Swing Fall Distance, Harness Stretch, Deceleration
Distance and Safety Factor.
C
LEARANCE
R
EQUIREMENT
WITH
O
FFSET
AND
S
ETBACK
D
ISTANCE
FOR
L
EADING
E
DGE
A
PPLICATIONS
FOR
R410065LE
S
ETBACK
D
ISTANCE
O
FFSET
D
ISTANCE
2 Foot
(0.6m)
4 Foot
(1.2m)
6 Foot
(1.8m)
8 Foot
(2.4m)
10 F
OOT
(3.0m)
12 Foot
(3.7m)
14 Foot
(4.3m)
16 Foot
(4.9m)
18 Foot
(5.5m)
20 Foot+
(6.1m)+
0 Foot (0m)
17.5 ft
(5.4m)
17.5 ft
(5.4m)
17.5 ft
(5.4m)
17.5 ft
(5.4m)
17.5 ft
(5.4m)
17.5 ft
(5.4m)
17.5 ft
(5.4m)
17.5 ft
(5.4m)
17.5 ft
(5.4m)
17.5 ft
(5.4m)
2 Foot (0.6m)
18.3 ft
(5.6m)
18.0 ft
(5.5m)
17.8 ft
(5.5m)
17.7 ft
(5.4m)
17.7 ft
(5.4m)
17.7 ft
(5.4m)
17.6 ft
(5.4m)
17.6 ft
(5.4m)
17.6 ft
(5.4m)
17.6 ft
(5.4m)
4 Foot (1.2m)
20.0 ft
(6.1m)
19.2 ft
(5.9m)
18.7 ft
(5.7m)
18.4 ft
(5.6m)
18.3 ft
(5.6m)
18.1 ft
(5.5m)
18.1 ft
(5.5m)
18.0 ft
(5.5m)
17.9 ft
(5.5m)
17.9 ft
(5.5m)
6 Foot (1.8m)
20.7 ft
(6.3m)
20.0 ft
(6.1m)
19.5 ft
(5.9m)
19.2 ft
(5.9m)
18.9 ft
(5.8m)
18.7 ft
(5.7m)
18.6 ft
(5.7m)
18.5 ft
(5.6m)
18.4 ft
(5.6m)
8 Foot (2.4m)
21.5 ft
(6.6m)
20.8 ft
(6.3m)
20.3 ft
(6.2m)
19.9 ft
(6.1m)
19.6 ft
(6.0m)
19.4 ft
(5.9m)
19.2 ft
(5.9m)
19.0 ft
(5.8m)
10 Foot (3.0m)
21.1 ft
(6.4m)
20.7 ft
(6.3m)
20.4 ft
(6.2m)
20.1 ft
(6.1m)
19.9 ft
(6.1m)
DO NOT
USE
E
XAMPLE
:
With the SRL-LE anchor set back 10 feet from the edge, the user can work up to 8 feet
(2.4m) offset along the leading edge. The required clearance is 20.3 feet (6.2 m) from the working
level to the nearest obstruction below.
The required clearance includes; Free Fall and Swing Fall Distance, Harness Stretch, Deceleration
Distance and Safety Factor.