RS232 Hi Power Data Sheet P.11
Example:
when GID=1234 and transmitted side which UID=0A send data to
receive side which UID=2A, GID=0000. But equipment which UID=2A can’t
receive any data, only GID=1234 can receive data from receive side which
UID=2A.
Detect interface rate:
please switch interface rate and input 72bytes of 0X8D
when you can’t make sure the interface rate. Equipment side will return same
0x8D, total are 72bytes when interface rate is correct.
Address
Read/Write
Byte
Default(Hex)
Range(Hex)
0x8D
R
72
-
8D8D8D
~
8D
Cancel transfer station:
input 72bytes of 0X8F for one time when you need to
cancel transfer station. When receiver side returns same 0X8F, total are 72bytes,
it is meaning you cancel preset transfer station. You need to collocate with
point-to-point transmission format after you cancel transfer station so that you
just can start to normal working.
Address
Read/Write
Byte
Default(Hex)
Range(Hex)
0x8F
W
72
-
8F8F8F
~
8F
Preset transfer station:
this function needs to preset constant path of data
transmission mode. After finish preset, every data doesn
’t need to add any
command and path, but the data which you send every time must be less than 64
bytes. Equipment will automatically transfer and send data according to preset
path. Maximum transfer stations you can set are 10. Setting way is to add UID
number on finial receiver side behind the command. If you need to go through
transfer station, you need to insert UID number of path in the middle.
GID:1234
UID:2A
GID:1234
UID:0A
GID:0000
UID:2A
Transfer data=ABCDEF
Only GID=1234 Receive
Receive data=ABCDEF
Non receive data