EN
30
Technical Data
Signal Output, Signal (not safety-relevant)
Signal output
Semiconductor, PNP output, short-circuit proof
Number of signal outputs
1
Utilization category
DC-13
Rated operating current Ie2
250 mA
Rated operating voltage Ue2
24 V
Electromagnet Activation, Mag
Voltage range
−3 to 5 V (low), (stabilized PELV power pack per EN 60204-1)
15 to 30 V (high), (stabilized PELV power pack per EN 60204-1)
typically 10 mA / 24 V, 20 mA dynamic
Accepted test pulse duration to input signal
≤
5,0 ms
With a test pulse interval of
≥
40 ms
ZVEI classification
ZVEI CB24I
Source
C1, C2, C3
Sink
C0
Mechanical Data
Housing material
Fiberglass reinforced plastic, self-extinguishing thermoplastic
Connector type
M12×1, 8-pin
Tightening torque
8 Nm
Vibration resistance
10 to 150 Hz (0.35 mm / 5 g)
Shock resistance
30 g / 11 ms
Locking force F
max
, typical
750 N
Locking force F guaranteed
500 N
Assured switching distance sao
0 mm
Assured switch-off distance sar
1 mm
Service life
≥
1,000,000 switching cycles
(with door weights of
≤
5 kg, actuating speed:
≤
0.5 m/s)
Latching force
• SD4ICS01SE89
• SD4ICS02SE89
• SD4ICS03SE89 / SD4ICS13SE89
• SD4ICS04SE89 / SD4ICS14SE89
—
typically 15 N
typically 30 to 100 N
typically 45 to 115 N
Technical Safety Data
Safety Category (EN ISO 13849-1)
4
Safety integrity level (EN 61508)
Suitable for SIL 3 applications
Performance level (EN ISO 13849-1)
To PL e
PFHD
3.54 × E–9 1 / hr.
Service life TM (EN ISO 13849-1)
20 years
Function
Operating principle
Inductive
Lock
Electromagnetic
Coding level (EN ISO 14119)
Low
Series connection
Unlimited number of devices, note external line protection,
max. sensor string length: 200 m
NOTE!
The cable length and cross-section change the volt-
age drop depending on the output current.