7.5 A1 Analog/Analog
The measuring range for the analog output can be feely selected within the specified working range with rising
of falling characteristic curve.
The adjusted measuring range must have a value of at least 2 % of the total measuring range.
Designation
Function
Key designation
Mode U/I
Analog output as current or voltage output
U
I
The analog output can be set up as either a current or a voltage output by pressing the
U or the I key.
The corresponding symbol is displayed.
Teach
Teach in the distances which correspond to the
upper and lower voltage values
10 V
respectively
20 mA
0 V
respectively
4 mA
The momentary actual distance is assigned to a voltage value of
10 V or a current value of 20 mA by
pressing the 10 V or the 20 mA key.
The momentary actual distance is assigned to a voltage value of
0 V or a current value of 4 mA by
pressing the 0 V or the 4 mA key.
If necessary, the assigned distances can be readjusted with the help of menu items At
0 V or at 10 V.
at 0 V
Distance at 0 V
+
–
The distance assigned to either 0 V or 4 mA is adjusted by pressing the + or the – key.
at 10 V
Distance at 10 V
+
–
The distance assigned to either 10 V or 20 mA is adjusted by pressing the + or the – key.
Содержание OY1TA603P0003
Страница 31: ...31 Sensoren f r Ihren Erfolg www wenglor com Sensoren f r Ihren Erfolg www wenglor com DE...
Страница 61: ...61 Sensors for your success www wenglor com Sensors for your success www wenglor com EN...
Страница 62: ...62 Sensors for your success www wenglor com Sensors for your success www wenglor com EN...
Страница 63: ...63 Sensors for your success www wenglor com Sensors for your success www wenglor com EN...