16
Installation and Electrical Connection
5.6.2 Troubleshooting
Error
Possible Cause
Elimination
Warning
Adjustment aid for displaying the
unsafe range
Active at: 0.8 × Sr min < S
≤
Sr min
Example
Sn = 1 mm, i.e. Sr min = 0.9 mm
Adjustment aid active: 0.72…0.9 mm
Reduce the distance between the
sensor and the object
• Distance must be < 0.8 × Sr min
Example
Object distance < 0.71 mm
Error
Short circuit
Check the electrical wiring and elimi-
nate the short circuit
Mechanical damage to the coil
Replace the sensor
Required Action in Case of Fault:
NOTE!
• Shut down the machine.
• Analyze and eliminate the cause of error with the aid of the diagnostics information.
• If the error cannot be eliminated, please contact wenglor’s support department
• Do not operate in case of indeterminate malfunctioning.
• The machine must be shut down if the error cannot be definitively explained or properly
eliminated.
DANGER!
Risk of personal injury or property damage in case of non-compliance!
The system’s safety function is disabled. Personal injury and damage to equipment may
occur.
• Required action as specified in case of fault.