STORING THE PRESSURE WASHER FOR EXTENDED PERIODS:
1. Drain the fuel tank (see “Draining the Fuel Tank” in the “Maintenance” section).
2. Change oil.
3. Do not obstruct any ventilation openings.
4. Keep the pressure washer in a cool dry area.
TRANSPORTING THE PRESSURE WASHER:
1. Tighten fuel cap. Drain the fuel tank if possible.
2. Always keep the pressure washer upright. Do not lay it down sideways.
STORAGE & TRANSPORT
TROUBLESHOOTING
WARNING:
Stop using the tool immediately if any of the following problems occur. Repairs and
replacements should only be performed by an authorized technician. For any questions, please contact
our customer service at (800) 232-1195, M-F 8-5 CST or email us at [email protected].
PROBLEM
CAUSE
SOLUTION
Engine will not start
Engine switch is set to “OFF”
Set engine switch to “ON”
Fuel valve is turned to “OFF:
Turn fuel valve to “ON” position
Choke is open
Close the choke
Engine is out of fuel
Add gasoline
Engine is filled with contaminated or old gasoline
Change the gasoline in the gas tank
Spark plug is dirty
Clean spark plug
Spark plug is broken
Replace spark plug
Generator is not on level surface
Move generator to a level surface to prevent low
oil shutdown from triggering
Oil is low
Add or replace oil
Water pressure is weak
Water supply is restricted
Inspect garden hose for leaks. Make sure you are
using a large enough hose (min. 3/4” diameter)
Water is not turned on to full power
Open water source all the way
Not using high pressure nozzle
Change nozzle
Detergent and spray do not mix
Detergent hose is not submerged or has disconnected
Make sure hose is connected and submerged in
the detergent
Black soap nozzle needed
Use soap nozzle
Pump fails to produce pressure or
pressure is inconsistent
Water supply is restricted
Inspect garden hose for leaks. Make sure you are
using a large enough hose (min. 3/4” diameter)
Water not turned on full power
Open water source all the way
Nozzle is clogged
Clean nozzle
Spray gun leaks
Check spray gun connection or replace spray gun
Air in line
Squeeze trigger handle to remove air
Inlet hose screen is clogged
Clean inlet
Water supply is over 100° F
Use cool water supply
Pump is faulty
Contact customer service at 1-800-232-1195 for
assistance.
22