14.  DO NOT use the plug to start and to stop the unit. Always use the control panel to start and 

to stop the unit.

15.  Always turn off the unit when it is not in use and unplug the power plug from the electrical 

outlet.

16.  Always turn the unit off and unplug the main power plug from the electrical outlet before 

cleaning, moving or performing maintenance.

17.  AVOID the use of adapter plugs or extension cords. If it is necessary to use an extension cord 

or an adapter plug to operate the unit, ensure that they are correctly rated for the applica-

tion. Consult a local qualified lectrician and all local electrical codes to ensure proper setup. 

Any extension cord used with this device must be rated for a minimum of 15A.(120V)

18.  DO NOT unplug the unit by pulling on the electrical cord. Keep electrical cord away from heat 

sources and always completely unroll the cord to avoid overheating. If the power cord be-

comes damaged, a qualified service agent, qualified electrician, or similarly qualified person 

must replace it, in order to avoid a hazard or shock.

DO NOT operate the unit in explosive or flammable environments.

DO NOT operate a unit with a damaged power cord.

19.  The filters must be used with the product at all times. When the filters are removed for clean-

ing, always ensure that the unit has been turned off and unplugged from the electrical outlet.

20.  Regularly clean the filters to maintain efficiency. If the filters are not cleaned regularly, the 

units output performance and efficiency will decline and energy consumption will increase.

21.  DO NOT operate the unit with a damaged power cord or plug, after it malfunctions, has been 

dropped or damaged.

22.  Only use in the upright position on an even, flat surface. Unit must be positioned at least 24 

inches (60 cm) from the nearest object in any direction.

23.  Stop operation immediately if abnormal noise or odor is noticed. Contact a local service 

center.

24.  Appliance is not to used by children or persons with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or 

instruction.

25. Children being supervised not to play with appliance.

26. That the appliance shall be installed in accordance with national wiring regulations.

27.  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 

similarly qualified persons in order to avoid a hazard.

SAVE THESE INSTRUCTIONS

Содержание Icen WPD-120

Страница 1: ...mid ity and faults If an abnormal operation occurs a visual display of the fault is shown Caster wheels are included for easy portability Suitable applications include a factory or work place industri...

Страница 2: ...ys place the unit on an even level surface 3 Ensure the unit is connected to a grounded power supply of the correct rating capacity 4 The unit is designed to operate under 5 C 41 F 35 C 95 F and RH ma...

Страница 3: ...ble environments DO NOT operate a unit with a damaged power cord 19 The filters must be used with the product at all times When the filters are removed for clean ing always ensure that the unit has be...

Страница 4: ...t is for controlling the function handle EVAPORATOR It is where humid air goes in Control box Filter Caster It makes the unit easy to move Condensate outlet It is where condensate comes out connected...

Страница 5: ...r any other foreign material The unit is equipped with an approved NEMA plug configuration WPD 120 5 15P The appropriate outlet must be used for each plug type WARNINGS REGARDING PROPER LOCATION FOR I...

Страница 6: ...splay is turned on during dehumidification mode whereas it is turned off when it is not on dehumidification mode It is controlled based on dehumidification sensor and relative humidity is displayed 2...

Страница 7: ...essing dehumidification button or selecting set time During setting mode user controls setting range by pressing the UP and DOWN button Setting range 0 12 hrs it is either increased or decreased by 30...

Страница 8: ...the filter in a shaded area before replacing it Do not operate the unit without the filter installed and the filter guard in the closed position 5 Replace the clean filter and close the filter grill...

Страница 9: ...anual for future reference and keep sales receipt as proof of purchase SELF DIAGNOSTIC CODES See Table 1 The alarm light is activated if abnormal operation occurs and a code is displayed on the contro...

Страница 10: ...FS NCJFOU UFNQFSBUVSF JT UPP IJHI NCJFOU UFNQFSBUVSF JT UPP IJHI 6OTUBCMF WPMUBHF TVQQMZ FGFDUJWF DPNQSFTTPS 0WFS DVSSFOU SFMBZ EFGFDU PS CSPLFO DPOOFDUJPO 5 EFIVNJEJGJDBUJPO TFOTPS IBT B MPPTF PS CSP...

Страница 11: ...11 Owner s Manual WPD 120 Wiring Diagram Figure 7 Circuit Wiring Diagram WPD 120 WPD 120 150 0 6...

Страница 12: ...nstallation or use of products Product Suitability Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary fr...

Отзывы: