Owner’s Manual

WPD-120

Maintenance 

(Continued)

–  To ensure your product is covered by warranty, the complete faulty product along with your 

original purchase receipt must be provided at the place of purchase.

Product

Portable Dehumidifier

Model No.
Date of Purchase
Place of Purchase
Serial No.
Period of Warranty

Customer: Please read and keep this 

manual for future reference and keep 

sales receipt as proof of purchase.

SELF-DIAGNOSTIC CODES 

(See Table 1)

The alarm light is activated if abnormal operation occurs, and a code is displayed on the control 

panel. The compressor and condenser fan motor will stop operating. The evaporator fan will con-

tinue to run for 3 minutes. If the fault is rectified within 3 minutes, the unit will resume opera-

tion. If the fault persists for more than 3 minutes, the evaporator fan also stops. The fault must 

be rectified before the unit can resume normal operation.

 

Содержание Icen WPD-120

Страница 1: ...mid ity and faults If an abnormal operation occurs a visual display of the fault is shown Caster wheels are included for easy portability Suitable applications include a factory or work place industri...

Страница 2: ...ys place the unit on an even level surface 3 Ensure the unit is connected to a grounded power supply of the correct rating capacity 4 The unit is designed to operate under 5 C 41 F 35 C 95 F and RH ma...

Страница 3: ...ble environments DO NOT operate a unit with a damaged power cord 19 The filters must be used with the product at all times When the filters are removed for clean ing always ensure that the unit has be...

Страница 4: ...t is for controlling the function handle EVAPORATOR It is where humid air goes in Control box Filter Caster It makes the unit easy to move Condensate outlet It is where condensate comes out connected...

Страница 5: ...r any other foreign material The unit is equipped with an approved NEMA plug configuration WPD 120 5 15P The appropriate outlet must be used for each plug type WARNINGS REGARDING PROPER LOCATION FOR I...

Страница 6: ...splay is turned on during dehumidification mode whereas it is turned off when it is not on dehumidification mode It is controlled based on dehumidification sensor and relative humidity is displayed 2...

Страница 7: ...essing dehumidification button or selecting set time During setting mode user controls setting range by pressing the UP and DOWN button Setting range 0 12 hrs it is either increased or decreased by 30...

Страница 8: ...the filter in a shaded area before replacing it Do not operate the unit without the filter installed and the filter guard in the closed position 5 Replace the clean filter and close the filter grill...

Страница 9: ...anual for future reference and keep sales receipt as proof of purchase SELF DIAGNOSTIC CODES See Table 1 The alarm light is activated if abnormal operation occurs and a code is displayed on the contro...