![Weltem Americool HPC-3000 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/weltem/americool-hpc-3000/americool-hpc-3000_owners-manual_956099015.webp)
page
15
Owner’s Manual
HPC-3000 / WPC-4000 / HPC-5000 / WPC-7000 / WPC-9000 / WPC-15000
6. ALARM
• Alarm indicator light blinks and indicates abnormal system operation.
• If Alarm occurs, compressor stops.
• System operation stops when ALARM light is activated /blinking longer than
3 minutes.
7. CURRENT TEMP
• Room cool mode displays current room temperature in display in Fahren-
heit
• SPOT / COOL Mode displays outlet (cool air) temperature during normal
operations.
• In order to change °F to °C, press SPOT / COOL and ROOM / COOL buttons
together for 2 seconds.
• C will blink 2 times and the figure will change to °C
• ALARM codes blink and are displayed when abnormal operation occurs.
8. TARGET TEMP
• Displays the unit set temperature for ROOM COOL mode only
OFF-TIMER:
Enter to Timer Setting Mode if you press BLOWER Button and SPOT/
COOL Button together for 1 seconds. Press UP/DOWN Button to set the timer un-
til it shows the figure you want to set. After 5 seconds, the figure will be memo-
rized and the compressor will stop after the time set.
AUTO RESTART:
If the unit goes off due to an electrical interruption, the unit will
automatically restart when the power resumes.
MAINTENANCE
Filter Cleaning
1. To clean the evaporator filter, pull the front filter guard forward from the top
until the guard is open (in an angled position) and resting on the supporting
cables.
2. Slide the filter up and use a vacuum cleaner to remove the dust from the
filter.