Wells WV-4HSRW Скачать руководство пользователя страница 15

OPERATION 

CAUTION: 

Hot Surface 
 

Exposed surfaces can be hot 
to the touch and may cause 
burns. 

VENTILATOR OPERATION 

 

1.     Press the VENTILATOR POWER switch to ON.  The green      
       

VENTILATOR POWER 

light will glow and the blower fan will start. 

        After a short time, if all filters are sensed as being in position and 
        not clogged, the cooktop will be energized.  The roll warmer is    
        energized at all times.  
        During normal operation, the 

VENTILATOR POWER

 light will be 

        the only light glowing on the upper control panel. 

 

2.     If the amber 

CHECK FILTER

 light glows, one or more filter         

        elements is out of position.  Check the GREASE BAFFLE,       
        PRE-FILTER and FILTER PACK for proper installation in their    
        respective positions.  Grease baffle and filter pack position are     
        sensed by mechanical switches.  Pre-filter position is sensed by a 
        vacuum switch. 

 

3.     When the amber 

REPLACE PRE-FILTER

 light glows, the pre-filter 

        is nearing the end of its service life.  Replace the disposable    
        PRE-FILTER ELEMENT. 

 

4.     When the amber 

REPLACE FILTER PACK

 light illuminates, the   

        HEPA / Charcoal filter pack is nearing the end of its service life.     
        Replace the FILTER PACK. 

 

       

Note:  

The 

REPLACE PRE-FILTER

  and 

REPLACE FILTER PACK 

       

lights are a warning that the indicated filter is near the end of its 

        service life.  The appliance will continue to operate for a period of 
        time after the light  glows to allow continued operation through a 
        peak period. However, the indicated filters must be replaced within 
        a reasonably short time period or they will clog and shut down    
        electrical power to the cooktop.  The ventilator blower will continue 
        to run. 

 

5.     When the red 

SERVICE REQUIRED

 light glows, either the           

        pre-filter or filter pack (or both) is clogged and can no longer pass  
        sufficient air to allow further operation.  The ventilator fan continues 
        to run, but the cooktop is shut down until the underlying clogged 
        filter situation has been corrected.  This  can occur when neither 
       

CHANGE...FILTER 

indicator light is lit, if both pre-filter and filter 

        pack are marginal.  Replacing both the pre-filter and the filter pack 
        will remedy the situation. 

 
        Note:  

replacing the pre-filter, even   though not very dirty, will often 

        extend the service life of the more expensive filter pack. 
 
        Reset the unit by turning the 

VENTILATOR

 

POWER 

switch to 

       

OFF

, then back 

ON

 

6.     A failure of incoming electrical power will cause a shut down of the 
        unit.  After power is restored, reset the unit by turning the          
       

VENTILATOR PO

WER switch to 

OFF

, then back 

ON

Fig. 10  Ventilator Indicator    
              and Warning Lights 

13 

Содержание WV-4HSRW

Страница 1: ...ual is considered to be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant or to the person responsible for TRAINING OPERATORS of this appliance Additional manuals are...

Страница 2: ...th electrical code requirements and wiring diagrams supplied with the equipment are not covered by this warranty 4 Replacement of items subject to normal wear to include such items as knobs light bulb...

Страница 3: ...ontains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS COOKTOP A C 3 1 MODEL EL...

Страница 4: ...9 16 18 23 9 8 a15 a11 53 12 41 44 42 43 40 a6 a31 38 18 16 22 23 VENTILATOR CONTROL PANEL see pages 4 5 COOKTOP CONTROL PANEL see pages 4 5 WARMER CONTROLS see pages 4 5 a10 70 38 Fig 1 Ventilator Se...

Страница 5: ...sion media discharges here 2 places Extracts and drains most grease and moisture from the air flow Comprises the PRE FILTER FRAME and a replaceable PRE FILTER Stops larger particles of grease from rea...

Страница 6: ...Features Controls Fig 3 Cooktop Section Controls Indicator Lights ROLL WARMER HUMITROL RACK DRAWER INSERT PAN COOKTOP SPIRAL HEATING ELEMENT DRIP PAN HEATING ELEMENT ROTATED ELEMENT SUPPORT SOLID PLAT...

Страница 7: ...replaced RED Glows when PREFILTER and or FILTER PACK has reached the end of its service life and is too loaded to allow sufficient air flow Filter MUST be replaced Appliance is SHUT DOWN until expende...

Страница 8: ...ess of this appliance is essential to good sanitation Read and follow all included cleaning instructions and schedules to ensure the safety of the food product Disconnect this appliance from electrica...

Страница 9: ...e someone available who is capable of replacing it Otherwise you may experience an extended down time with consequent associated loss of business The manufacturer assumes no liability for loss of busi...

Страница 10: ...IRE SUPPRESSION AGENT ANSULEX Low pH 1 5 GAL See Material Safety Data Sheet page 22 1 ea FIRE SUPPRESSION MEDIA TANK 1 ea FIRE SUPPRESSIONTANK CHARGING CARTRIDGE 1 ea GREASE BAFFLE 1 ea FILTER PACK AS...

Страница 11: ...1 Incoming wiring must comply with National Electrical Code specifications All cooktop universal hood appliances ship from the factory wired 3 and include a 3 cordset For 1 operation a Remove rear lo...

Страница 12: ...diately for service NOTE See page 22 for the Material Safety Data Sheet for the fire suppression agent 4 The MANUAL PULL STATION and any similar REMOTE MANUAL PULL STATION will activate the fire suppr...

Страница 13: ...p indentation of the lower filter rail 3 GREASE BAFFLE If the GREASE BAFFLE is not in place the CHECK FILTERS indicator will glow To install the GREASE BAFFLE Slide the grease baffle up into the inden...

Страница 14: ...2 Install the GREASE CUP on the right side of the unit directly below the grease trough HOTPLATE DRIP PAN INSTALLATION SPIRAL HEATING ELEMENTS ONLY 1 Lift rotate the elements up 2 Install a drip pan...

Страница 15: ...ACE FILTER PACK lights are a warning that the indicated filter is near the end of its service life The appliance will continue to operate for a period of time after the light glows to allow continued...

Страница 16: ...ntrol OFF removes power from the element LOW thru 8 are temperature settings Higher numbers indicate higher temperatures There is a continuous range of settings between LOW and HI HI is a continuous O...

Страница 17: ...may form e Check the water level in the pan periodically and add water when necessary f Set the front air vent between fully closed and half open Actual setting will depend upon the type and amount o...

Страница 18: ...rip pans and element supports may be washed in a sink or dishwasher Allow to air dry and reinstall Scrape burned on food debris from element using a plastic scraper or plastic scouring pad DO NOT use...

Страница 19: ...y TOOLS Warm water and a mild detergent Soft clean cloth or sponge Bristle brush Container for disposal of grease CLEANING Disconnect appliance from electric power Allow to cool before cleaning Ventil...

Страница 20: ...t appliance from electric power Allow to cool before cleaning FREQUENCY Monthly TOOLS Warm water and a mild detergent Soft clean cloth or sponge Plastic scouring pad plastic scraper Container for disp...

Страница 21: ...total operation including FIRE DAMPER and all SAFETY INTERLOCKS b All FIRE SUPPRESSION SYSTEM actuation components including MANUAL PULL STATION and any REMOTE MANUAL PULL STATION must be inspected fo...

Страница 22: ...20...

Страница 23: ...21...

Страница 24: ...Wt Wt CAS No CAS No ACGIH TLV ACGIH TLV Acute Toxicity Data Acute Toxicity Data None Proprietary Mixture of Organic and Inorganic Salts 48 0 50 0 Phosphoric Acid 0 2 7664 38 2 Yellow Green Fluorescent...

Страница 25: ...itation persists seek medical attention Dilute by drinking large quantities of water Respiratory Protection Specify Type N A N A N A Ventilation Local Exhaust Mechanical General Protective Gloves Rubb...

Страница 26: ...internal components Damaged internal components Temperature control not set Humidity control not set SUGGESTED ACTION Check reset circuit breaker Contact Authorized Ansul Distributor for repairs Obser...

Страница 27: ...or factory authorized service or to order factory authorized replacement parts contact your Wells authorized service agency or call Wells Manufacturing Co 2 Erik Circle P O Box 280 Verdi NV 89439 phon...

Страница 28: ...WELLS MANUFACTURING COMPANY DIVISION OF CARRIER REFRIGERATION 2 ERIK CIRCLE P O Box 280 Verdi NV 89439 Customer Service 775 345 0444 Ext 502 fax 775 345 0569 www wellsbloomfield com...

Отзывы: