Wells WV-4HSRW Скачать руководство пользователя страница 11

SERVICE TECHNICIAN INSTALLATION NOTES 

 

An Ansul® technician must charge and arm the fire suppression system 
before the ventilator blower will operate. See page 10. 

 

Installation and start up must be performed by an  Authorized            
Installation Company. 

 

Installer must complete the 

WARRANTY REGISTRATION 

 form, and 

record appliance installation particulars on the 

CUSTOMER SERVICE 

DATA

 form in this manual.  

 

Certain codes require cooking equipment  to be restrained with a      
RESTRAINT DEVICE.  It is the RESPONSIBILITY OF THE               
INSTALLER to check with the AUTHORITY HAVING JURISDICTION, 
in order  to ascertain the applicability of this requirement to THIS    
SPECIFIC EQUIPMENT INSTALLATION.  Any restraint device must 
allow access to the back and sides of the unit to provide for servicing 
and maintenance, and must not interfere with the operation of the FIRE 
SUPPRESSION SYSTEM. 
 

ELECTRICAL INSTALLATION

 

 
Refer to the nameplate on the cooking appliance to verify the           
ELECTRICAL SERVICE POWER.  Voltage and phase must match the 
nameplate specifications, and available electrical service amperage 
must meet or exceed the  specifications listed on page 1.  Incoming  
wiring must comply with National Electrical Code specifications. 
 
All cooktop / universal hood appliances ship from the factory wired 3ø 
and include a 3ø cordset. 

 

For 1ø operation: 
        a.    Remove rear lower panel (item 12) 
        b.    Refer to the wiring schematic diagram located on the inside of 
               the panel. 
        c.    Service wiring and conduit, or appropriate cordset must be    
               provided by the electrical installer. 
        d.    Wiring change must be performed by a licensed electrician. 
        e.    Be sure to reinstall the panel when wiring change is completed. 

IMPORTANT! 

Verify that this VENTILATOR 
and food cooking equipment 
installation is in compliance 
with the specifications listed 
in this manual, with local 
code requirements, and in 
accordance with N.F.P.A 96 
(

THE

 

STANDARD FOR 

VENTILATION CONTROL 
AND FIRE PROTECTION 
OF  COMMERCIAL     
COOKING OPERATIONS

  - 

current edition).  
 

THIS IS THE                     

RESPONSIBILITY              

OF THE INSTALLER 

 
 
 
 

DANGER 

 

ELECTRIC SHOCK       
HAZARD 
 

ELECTRIC CONNECTIONS 
MUST BE MADE BY A     
LICENSED ELECTRICIAN 
Electrical shock will cause 
death or serious injury. 
 
 
NOTE:  This appliance       
requires a dedicated 60 Amp 
electrical branch circuit     
protection. 
 

IMPORTANT: 

Contact a licensed electrician 
to install and connect      
electrical power to the        
appliance. 

 

IMPORTANT: 

Damage due to being 
connected to the wrong     
voltage or phase is NOT    
covered by warranty. 

INSTALLATION (continued) 

Содержание WV-4HSRW

Страница 1: ...ual is considered to be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant or to the person responsible for TRAINING OPERATORS of this appliance Additional manuals are...

Страница 2: ...th electrical code requirements and wiring diagrams supplied with the equipment are not covered by this warranty 4 Replacement of items subject to normal wear to include such items as knobs light bulb...

Страница 3: ...ontains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS COOKTOP A C 3 1 MODEL EL...

Страница 4: ...9 16 18 23 9 8 a15 a11 53 12 41 44 42 43 40 a6 a31 38 18 16 22 23 VENTILATOR CONTROL PANEL see pages 4 5 COOKTOP CONTROL PANEL see pages 4 5 WARMER CONTROLS see pages 4 5 a10 70 38 Fig 1 Ventilator Se...

Страница 5: ...sion media discharges here 2 places Extracts and drains most grease and moisture from the air flow Comprises the PRE FILTER FRAME and a replaceable PRE FILTER Stops larger particles of grease from rea...

Страница 6: ...Features Controls Fig 3 Cooktop Section Controls Indicator Lights ROLL WARMER HUMITROL RACK DRAWER INSERT PAN COOKTOP SPIRAL HEATING ELEMENT DRIP PAN HEATING ELEMENT ROTATED ELEMENT SUPPORT SOLID PLAT...

Страница 7: ...replaced RED Glows when PREFILTER and or FILTER PACK has reached the end of its service life and is too loaded to allow sufficient air flow Filter MUST be replaced Appliance is SHUT DOWN until expende...

Страница 8: ...ess of this appliance is essential to good sanitation Read and follow all included cleaning instructions and schedules to ensure the safety of the food product Disconnect this appliance from electrica...

Страница 9: ...e someone available who is capable of replacing it Otherwise you may experience an extended down time with consequent associated loss of business The manufacturer assumes no liability for loss of busi...

Страница 10: ...IRE SUPPRESSION AGENT ANSULEX Low pH 1 5 GAL See Material Safety Data Sheet page 22 1 ea FIRE SUPPRESSION MEDIA TANK 1 ea FIRE SUPPRESSIONTANK CHARGING CARTRIDGE 1 ea GREASE BAFFLE 1 ea FILTER PACK AS...

Страница 11: ...1 Incoming wiring must comply with National Electrical Code specifications All cooktop universal hood appliances ship from the factory wired 3 and include a 3 cordset For 1 operation a Remove rear lo...

Страница 12: ...diately for service NOTE See page 22 for the Material Safety Data Sheet for the fire suppression agent 4 The MANUAL PULL STATION and any similar REMOTE MANUAL PULL STATION will activate the fire suppr...

Страница 13: ...p indentation of the lower filter rail 3 GREASE BAFFLE If the GREASE BAFFLE is not in place the CHECK FILTERS indicator will glow To install the GREASE BAFFLE Slide the grease baffle up into the inden...

Страница 14: ...2 Install the GREASE CUP on the right side of the unit directly below the grease trough HOTPLATE DRIP PAN INSTALLATION SPIRAL HEATING ELEMENTS ONLY 1 Lift rotate the elements up 2 Install a drip pan...

Страница 15: ...ACE FILTER PACK lights are a warning that the indicated filter is near the end of its service life The appliance will continue to operate for a period of time after the light glows to allow continued...

Страница 16: ...ntrol OFF removes power from the element LOW thru 8 are temperature settings Higher numbers indicate higher temperatures There is a continuous range of settings between LOW and HI HI is a continuous O...

Страница 17: ...may form e Check the water level in the pan periodically and add water when necessary f Set the front air vent between fully closed and half open Actual setting will depend upon the type and amount o...

Страница 18: ...rip pans and element supports may be washed in a sink or dishwasher Allow to air dry and reinstall Scrape burned on food debris from element using a plastic scraper or plastic scouring pad DO NOT use...

Страница 19: ...y TOOLS Warm water and a mild detergent Soft clean cloth or sponge Bristle brush Container for disposal of grease CLEANING Disconnect appliance from electric power Allow to cool before cleaning Ventil...

Страница 20: ...t appliance from electric power Allow to cool before cleaning FREQUENCY Monthly TOOLS Warm water and a mild detergent Soft clean cloth or sponge Plastic scouring pad plastic scraper Container for disp...

Страница 21: ...total operation including FIRE DAMPER and all SAFETY INTERLOCKS b All FIRE SUPPRESSION SYSTEM actuation components including MANUAL PULL STATION and any REMOTE MANUAL PULL STATION must be inspected fo...

Страница 22: ...20...

Страница 23: ...21...

Страница 24: ...Wt Wt CAS No CAS No ACGIH TLV ACGIH TLV Acute Toxicity Data Acute Toxicity Data None Proprietary Mixture of Organic and Inorganic Salts 48 0 50 0 Phosphoric Acid 0 2 7664 38 2 Yellow Green Fluorescent...

Страница 25: ...itation persists seek medical attention Dilute by drinking large quantities of water Respiratory Protection Specify Type N A N A N A Ventilation Local Exhaust Mechanical General Protective Gloves Rubb...

Страница 26: ...internal components Damaged internal components Temperature control not set Humidity control not set SUGGESTED ACTION Check reset circuit breaker Contact Authorized Ansul Distributor for repairs Obser...

Страница 27: ...or factory authorized service or to order factory authorized replacement parts contact your Wells authorized service agency or call Wells Manufacturing Co 2 Erik Circle P O Box 280 Verdi NV 89439 phon...

Страница 28: ...WELLS MANUFACTURING COMPANY DIVISION OF CARRIER REFRIGERATION 2 ERIK CIRCLE P O Box 280 Verdi NV 89439 Customer Service 775 345 0444 Ext 502 fax 775 345 0569 www wellsbloomfield com...

Отзывы: