background image

Owners Manual f

or V

entles

s Do

wndr

aft Induction Range T

op

10

Control Panel

NOTE:  Cooking appliances must be operated in accordance with the manufacturer’s instructions.

During normal operation, the illuminated power switch will be the only light on the control panel 

that will be ON.

If the CHECK FILTERS light illuminates, check BAFFLE FILTERS, PREFILTERS, and the HEPA AIR 

FILTERS for proper installation.

If the REPLACE PRE-FILTERS light illuminates .. Replace the Pre-filters.

If the REPLACE FILTER PACK light illuminates, replace the FILTER PACK. 

NOTE: the REPLACE FILTERS PACK light is a warning that filter pack is nearing  the end of its 

service life.  The ventilator will continue to operate for a period of time after the REPLACE FILTER 

PACK LIGHT turns ON to allow continued operation through a peak period.  However, filter pack 

must be replaced within a short time period or it will clog, disabling the ventilator and appliances.

If the SERVICE REQUIRED light illuminates, the filter pack is restricted to the point of insufficient 

airflow for proper operation and the Ventilator will shut down until the underlying clogged filter 

situation has been corrected.  Replace clogged item with a fresh filter to correct the condition.   

Reset the unit by turning VENTILATOR POWER SWITCH to OFF,  

then back to ON.

A failure of incoming electric power will cause a shut down of the unit.  Reset the unit by turning 

VENTILATOR POWER SWITCH to OFF, then back to ON.

Operation Lights

There is one equipment light that provides illumination of the working area.  This light is controlled 

by the main power switch.

SERVICE

REQUIRED

REPLACE

FILTER PACK

REPLACE

PREFILTER

CHECK

FILTER

ON

POWER

OFF

IL2736

Содержание WDDI-31

Страница 1: ...Street Smithville Tennessee 37166 Telephone 800 264 7827 Fax 314 781 5445 www wells mfg com WDDI 35 VENTLESS DOWNDRAFT INDUCTION RANGE TOP MODEL WDDI 31 WDDI 35 Installation and Operation Instructions...

Страница 2: ...nge Top 2 TABLE OF CONTENTS GENERAL WARRANTY SAFETY INFORMATION INSTALLATION INFORMATION DAILY OPERATION CLEANING TROUBLESHOOTING FEATURES INSTALLATION CONTROL PANEL EXPLODED VIEW PARTS WIRING DIAGRAM...

Страница 3: ...type Normal Business Hours 8 00 a m to 4 30 p m Central Telephone 800 264 7827 Tech Service Option 2 Email TechService partstown com www Wells Mfg com WARRANTY EXCLUSIONS THE FOLLOWING WILL NOT BE COV...

Страница 4: ...ase have the information in the above fields ready when you call to ensure a faster service Using any part other than genuine Wells factory supplied parts relieves the manufacturer of all liability Du...

Страница 5: ...uld keep a minimum of 2 4 inches 51 102 mm of space between them and the cooking zone whenever possible It is recommended that you keep this distance at minimum whenever the unit is powered on Failure...

Страница 6: ...mber on page ii of this manual Read and understand all labels and diagrams attached to the downdraft Carefully account for all components and accessories before discarding packing materials COMPONENTS...

Страница 7: ...e federal state province and or local electrical codes having jurisdiction by a licensed electrician All electrical connections must be made with COPPER WIRE ONLY in the correct wire gauge for the app...

Страница 8: ...o wipe away and spilled food and debris If there is any hardened residue use a scraper or cleaning pad made specifically for glass ceramic surfaces and an appropriate glass ceramic cooktop cleaning so...

Страница 9: ...ocedure 1 TURN POWER SWITCH TO OFF 2 Remove BAFFLE FILTERS and GREASE CUP 3 Empty GREASE CUP into an appropriate grease collection receptacle 4 Clean BAFFLE FILTERS and GREASE CUP in a sink or dishwas...

Страница 10: ...ime to turn off the power stopping the cooker immediately COOKTEK CONTROLLER If the unit does not initially power on make certain the unit is plugged in properly and that the power supply is the corre...

Страница 11: ...aning instructions and schedules to ensure the safety of the food product This appliance is not jet steam approved Do not direct water jet or steam jet at this appliance or at any control panel or wir...

Страница 12: ...th top supports ITEM 10 using screws ITEM 8 6 Run cord ITEM 9 thru plastic bushing ITEM 13 and down thru the plastic bushing on the left side of chassis top 7 Install both supports ITEM 12 ITEM 13 usi...

Страница 13: ...ad and understand Site Preparation before continuing with the installation of the hood 4 Determine the exact location of the downdraft unit 5 Place the unit into position 6 Complete the assembly of th...

Страница 14: ...cal power to the terminal block per the wiring diagram NOTE It is the responsibility of the electrical contractor to provide suitable wiring flexible or rigid conduit and an appropriate strain relief...

Страница 15: ...he GREASE CUP will allow grease and moisture from the BAFFLE FILTER to drop onto floor surfaces creating both a SAFETY HAZARD and a SLIP HAZARD The BAFFLE FILTERS PRE FILTERS and FILTER PACK actuate p...

Страница 16: ...PACK LIGHT turns ON to allow continued operation through a peak period However filter pack must be replaced within a short time period or it will clog disabling the ventilator and appliances If the SE...

Страница 17: ...E 37465 TERM BLOCK 3POLE 85AMP 1 ALL 7 2E Z14960 BODY CONTACTOR 1 ALL 8 2E Z24169 POWER SUPPLY 24 VDC 1 ALL 9 2E Z24102 END CLAMP DIST BLOCK 4 ALL 10 2J Z24013 CONTROL RED LION CUB5TCBO 4 ALL 11 2N Z2...

Страница 18: ...BLK 17 RED 16 BLK 2 RED 1 BLK 3 BLK 4 RED GND GRN GND GRN GRN 45 WHT REPLACE FILTER REPLACE PRE FILTER CHECK FILTER SERVICE REQ LED LIGHT TRANSFORMER OPTIONAL LIGHT OPTIONAL RED LION CONTROL SENSOR Y...

Страница 19: ...PA FILTER SWITCH CHANGE FILTER LIGHT OPERATES NEGATIVE 0 37 WC ACTIVATES 1 55 WC SHUT DOWN PRESSURE SWITCH SERVICE REQUIRED LIGHT OPERATES NEGATIVE 2 50 WC ACTIVATES NEGATIVE 1 55 WC NOTES UNLESS NOTE...

Страница 20: ...STAR MANUFACTURING INTERNATIONAL INC Star Holman Lang Wells Toastmaster 265 Hobson Street Smithville TN 37166 U S A Telephone 800 264 7827 Fax 314 781 5445 www wells mfg com...

Отзывы: