Wells INSTANT-ON H-2412G Скачать руководство пользователя страница 13

M228 2M-306916  OpM H-2412 Instant-On Dual Pilot Gas Hotplate

CLEANING INSTRUCTIONS

PREPARATION

Turn gas shut-off valve OFF before cleaning.

Allow hotplate to cool completely before cleaning.

FREQUENCY:  

Daily

TOOLS

Bristle Brush

Clean Cloth or Sponge

Mild Detergent

Cleaner Formulated for Stainless Steel

Warm Water

CLEANING

Turn gas shut-off valve OFF before cleaning.
Allow hotplate to cool completely before cleaning.
Remove grate and drip tray by lifting from cabinet. Slide actuator heads 

off actuator arms.  
Note position of front and rear burner assemblies in cabinet.  Remove 

burner assemblies. 
Clean food particles from grate, actuator heads, drip tray and crumb 

tray with warm water, mild detergent and a bristle brush.  Rinse with 

clean water.  Wipe dry with a soft clean cloth.
Examine burner assemblies.  Note position of air shutters before 

cleaning.  Clean food particles from burners with  warm water, mild 

detergent and a bristle brush.  Rinse by wiping with a soft cloth 

dampened with clean water.  Wipe exterior surfaces dry with a soft 

clean cloth.  Allow burners to air dry so that interior passages are 

completely free of water.
Wipe the outer portions of the hotplate cabinet with a clean soft cloth 

or sponge dampened with warm water and a mild detergent or cleaner 

formulated for cleaning stainless steel.  DO NOT use steel wool to 

clean hotplate cabinet.  Rinse by wiping hotplate cabinet with a clean 

soft cloth or sponge moistened with clean warm  water.  Dry cabinet by 

wiping with a clean soft dry cloth.
Examine burners to be sure the air shutters are in their proper position.

Reinstall burner assemblies in cabinet (see fig. 7, page 12):

Burner with short venturi is the REAR burner.
Venturi / air  shutter slides over left nozzle.

Fingers on burner bracket slide into rear notches in center brace.

Burner with long venturi is the FRONT burner.  
Venturi / air  shutter slides over right nozzle.

Fingers on burner bracket slide into front notches in center brace.

Turn shut-off valve ON and light pilot flame.

Reinstall drip tray, actuator heads and grate.
Procedure is complete.

WARNING: 

FIRE HAZARD

Shut off the gas 

supply valve before cleaning.

CAUTION: 

BURN HAZARD

Allow hotplate to cool        

completely before cleaning.

IMPORTANT:  DO NOT 

spill 

or pour water into controls, 

DO NOT

 submerge hotplate 

cabinet in water. Damage to 

internal components will
occur.  Damage to internal

components from water

damage is NOT

 

covered by

warranty.

DO NOT

 steel wool or

metal scouring pads to clean 

cabinet, drip tray or crumb 

tray.

Good sanitation is vital to the 

quality of the final food

product.  Be sure to clean 

in all corners and crevices 

where grease and other

cooking debris can

accumulate.

11

WARNING

Содержание INSTANT-ON H-2412G

Страница 1: ...peration or maintenance of this equipment OPERATION MANUAL for COUNTER TOP GAS HOTPLATE Model H 2412G INSTANT ON Includes INSTALLATION USE CARE 228 2M 306916 Rev G 04 18 Model H 2412G Instant On FOR Y...

Страница 2: ...ult of normal use within the time period and limitations defined in this warranty will at Wells discretion have the parts replaced or repaired by Wells or a Wells authorized service agency THIS WARRAN...

Страница 3: ...tion professional operation and consistent maintenance of this equipment will ensure that it gives you the very best performance and a long economical service life This manual contains the information...

Страница 4: ...ds food product at proper distance from burner flame Removable for easy cleaning DRIP TRAY Catches drippings Removable for easy cleaning ADJUSTABLE LEGS Allow for ventilation under hotplate Provide me...

Страница 5: ...upplied 4 legs properly installed The technical content of this manual including any parts breakdown illustrations and or adjustment procedures is intended for use by qualified technical personnel onl...

Страница 6: ...oroughly clean the appliance before use See Cleaning Instructions page 11 SETUP Setup the hotplate only on a firm level non combustible surface The hotplate must be leveled with a spirit level in its...

Страница 7: ...to the gas supply system must be black iron pipe or other material as approved by local ordinance for gas piping 2 Gas supply piping must be inside 3 8 diameter or greater 3 Use pipe sealant made spe...

Страница 8: ...be installed between the gas supply piping and the gas pressure regulator It is the responsibility of the gas piping installer toidentify the code requirement for a shut off valve Shut off valves mois...

Страница 9: ...ng a small flat blade screwdriver turn the screw clockwise to decrease the flame size or counter clockwise to increase the flame size Burner should light quickly and completely when burner actuator is...

Страница 10: ...pply has been shut off it may take several minutes to light the pilot as air in the piping and manifolds is purged The pilot flame must be lighted by hand Turn both control knobs to the full OFF posit...

Страница 11: ...DO NOT set anything on grate other than cookware to be heated Pilot flame may be extinguished if blocked Anything placed on the burners will open the gas valves which can cause a fire or explosion OP...

Страница 12: ...urn gas back on and light both pilots Control not on Turn temperature control to HI Set to desired setting when lit Water in burner Remove burner and dry thoroughly Damaged temperature control valve b...

Страница 13: ...and a mild detergent or cleaner formulated for cleaning stainless steel DO NOT use steel wool to clean hotplate cabinet Rinse by wiping hotplate cabinet with a clean soft cloth or sponge moistened wit...

Страница 14: ...CLEANING INSTRUCTIONS continued 12 Fig 7 Hotplate Assembly M228 2M 306916 OpM H 2412 Instant On Dual Pilot Gas Hotplate IL1643...

Страница 15: ...odel H 2412GIO COUNTERTOP GAS HOTPLATE PL228 1 2 3 4 5 10 9 11 12 13 8 19 14 15 16 17 18 34 19 Old Valve Design use kit WS WL0262 26 14 27 28 30 31 32 33 29 25 24 23 22 21 20 6 7 M228 2M 306916 OpM H...

Страница 16: ...14 WS 506860 KIT SERV H2412G ACTUATOR 15 M3 506919 TUBE SS 1 40 X 4 FLEX FR 16 2R 39325 KNOB CONTROL ASSY FRONT 17 2R 39327 KNOB CONTROL ASSY REAR 18 WS WL0262 MANUAL VALVE REPLACEMENT KIT 2V Z15185...

Страница 17: ...NO _______________ FUEL check one Natural Gas LP Propane PARTS SERVICE 17 DESCRIPTION SERVICE PART NO LEGS PLASTIC 4 2R Y5092 DRIP TRAY DUAL PILOT HOTPLATE I7 306706 GRATE STAINLESS STEEL I7 306707 IM...

Страница 18: ...WELLS MANUFACTURING 265 Hobson Street Smithville Tennessee 37166 telephone 314 678 6314 www wells mfg com...

Страница 19: ...eil MANUEL D UTILISATION pour PLAQUE CHAUFFANTE DE COMPTOIR GAZ Mod le H 2412G ALLUMAGE INSTANTAN Contenu INSTALLATION UTILISATION ET ENTRETIEN 228 2M 306916 Rev F 04 18 Mod le H 2412G Allumage instan...

Страница 20: ......

Страница 21: ...ri e un fonctionnement professionnel et un entretien r gulier de cet ap pareil permettront ce dernier de vous offrir un rendement optimal et une dur e de vie prolong e et conomique Ce manuel contient...

Страница 22: ...et arri re VEILLEUSE Procure la source d allumage pour les br leurs principaux ACTIONNEUR Permet le passage du gaz vers le br leur lorsqu il est enfonc T te d actionneur amovible pour un nettoyage ai...

Страница 23: ...quatement Le contenu technique de ce manuel y compris les illustrations clat es des pi ces et ou des proc dures de r glage est destin une utilisation par du personnel technique qualifi uniquement Tout...

Страница 24: ...utiliser Se reporter aux Instructions de nettoyage la page 11 INSTALLATION Installer la plaque uniquement sur une surface plane de niveau et non combustible La plaque doit tre nivel e l aide d un niv...

Страница 25: ...z doit pr senter un pas de tuyauterie d au moins po 3 Utiliser un scellant conduit fabriqu pr cis ment pour des conduits gaz sur tous les raccords de conduit Appliquer mod r ment le scellant uniquemen...

Страница 26: ...upape d arr t Les soupapes d arr t les purgeurs de condensat et tous les conduits connexes doivent tre fournis par l installateur des conduits de gaz DANGER RISQUE D INCENDIE ET D EXPLOSION NE JAMAIS...

Страница 27: ...la vis dans le sens des aiguilles d une montre pour r duire la taille de la flamme ou dans le sens inverse des aiguilles d une montre pour augmenter la taille de la flamme Le br leur devrait s allume...

Страница 28: ...er la veilleuse puisque l air dans les conduits et distributeurs doit d abord tre purg La flamme des veilleuses doit tre allum e manuellement Mettre les deux boutons de r glage compl tement la positio...

Страница 29: ...e autre que le chaudron chauffer La flamme de la veilleuse peut s teindre si elle est bloqu e Tout l ment plac sur les br leurs ouvrira les soupapes de gaz ce qui peut entra ner un incendie ou une exp...

Страница 30: ...euses R glage non la position ON Tourner le bouton de r glage de la temp rature la position HI R gler la temp rature d sir e une fois allum Eau dans le br leur Retirer le br leur et s cher fond Dommag...

Страница 31: ...ponge imbib e d eau chaude et d un d tergent doux ou d un nettoyant con u pour nettoyer l acier inoxydable NE PAS utiliser de laine d acier pour nettoyer le bo tier de la surface chauffante Rincer en...

Страница 32: ...e se fixe par le centre du br leur 4 ASSEMBLAGE DE LA GRILLE Se fixe au dessus des br leurs Les t tes de l activateur s enroulent autour de la tige centrale de la grille 3 PLATEAU D GOUTTAGE Se fixe e...

Отзывы: