Hose and Regulator (Comes standard with the side burner)
The Type 1 connection system has the follow-
ing features:
• The system will not allow gas to flow until
a positive connection has been made. The
cylinder control valve must be turned off
before any connection is made or re-
moved.
• The system has a thermal element that
will shut off the flow of gas in the event of
a fire.
• The system has a flow limiting device
which, when activated, will limit the flow of
gas to 10 cubic feet per hour.
• NEVER use side burner without leak testing this connection.
LP (Propane) Gas Supply Connection
1. The tank valve should be in the “OFF” position.
If not, turn the knob clockwise until it stops.
2. Make sure all burner valves are in the “OFF”
position.
3. Always connect the gas supply regulator as
follows:
Insert the regulator inlet into the tank valve and
turn the coupling nut clockwise until the coupler
tightens up (see picture). Do not over-tighten
the coupler. Turn the main tank valve on, and
turn the burner control valves on
4. The outdoor cooking gas appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off valve during any
pressure testing of the gas supply piping system at test pressures equal to
or less than 1/2 psi {3.5 kPa}. Rotate the knob to the “HIGH” position for
about 20 seconds to allow the air in the system to purge before attempting
to light the burners.
Check hose for breaks or wear
before each use
Type 1
Connector
Regulator