24
GB
Message/symptom
Possible cause
Remedial measures
Extraction power missing
Pipe system leaking
Reseal the pipe system
Filter is dirty
change the filter
Turbine speed too low
Increase the speed setting
Loud extraction noises
Air speed through extractionarm
is too high speed
Reduce the air speed (reduce air
quanitity)
Zero Smog is not running
Thermally switched off
Leave the Zero Smog to cool
down Switch on again afterap-
prox. 3 hours
Filter display is not
working
Minimum pressure hose was not
replaced after the filter change
Reconnect the hose to the filter
Particle filter depleted too
quickly
Pre-filter has not been used
Use a pre-filter Fit an F7 filter
Use a preliminary seperator if the
proportion of solid matter is high.
Unable to detect USB
medium
USB medium inserted too long
Do not leave USB medium
inserted for longer than 2
minutes. Remove USB medium
and switch unit off and on again
Reset unit
Wrong USB medium > 100 mA
Remove USB medium!
Error messages and error clearance
Care and maintenance
Notice
Different fluxes and flux
constituents and the amount
of and size of dust particles
in the extracted air will signifi
cantly effect the filters wor-
king life. A gas filter (without
particle filter) must be used
for the extraction of adhesive
fumes.
To ensure that the filtration system functions properly, the filter must
be replaced as follows
at least once a year or
when indicated or
if the maximum allowable workplace concentration is exceeded or
as per maintenance schedule
The degree of clogging of the filter is determined by differential pres-
sure measurement. The filter display indicates the current filter status
Red = filter full
Yellow = filter status > 80%
Green = filter status < 80%.
When the filter is used up, an audible signal sounds
once an hour
every half hour after 36 hours
every 10 min after 54 hours
continuously after 72 hours.
The particle filter and the gas filter are co-ordinated in such a way
that they can be replaced together as a compact filter unit. The com-
pact filter must be changed once a year in order to ensure it is fully
functional. The fine dust filter (filter mat) is the preliminary stage of
the compact filter and therefore must be replaced more frequently.It
is sufficient to replace the prefilter mat if the red LED does not come
on after restarting the unit.
Warning!
Before doing any work on
the machine, pull the plug
out of the socket.
Use original replacement
parts only.
Contaminated filters must be
treated as special waste.
Dispose of replaced equip-
ment parts, filters or old
devices in accordance with
the rules and regulations
applicable in your country.