We thank for the confidence you have shown by purchasing
the Weller Heating Plate WHP 1000. During manufacture the
strictest quality requirements are applied; these assure the
correct function of the device and make it possible to obtain
optimal soldering results. 

1. Attention!

Prior to placing the device in operation, please carefully read
these operating instructions and the safety instructions
enclosed. If the safety instructions are not observed, there is
a risk of injury.

The manufacturer accepts no liability for usage other than
that described in the operating instructions or for unauthori-
sed modifications

The WELLER heating plate WHP 1000 complies with the EU
declaration of conformity as per the essential safety 
requirements in the directives 2004/108/EU, 2006/95/EU
and 2011/65/EU (RoHS).

2. Description

The WHP 1000 heating plate is equipped with 4 heating 
elements, each 250 W and enable electronic assemblies to
be pre-heated in numerous ways. Digital regulation 
electronics ensure precise temperature behaviour and 
support various special functions such as “AUTO OFF” or
standby temperature. Setpoints and actual values are 
indicated digitally. 
With an optional external sensor, the temperature can be
regulated at specific needed spots.

An integrated RS232 interface enables the device to be 
controlled externally from the Weller WHA 3000P / 
WHA 3000V hot air station. Here the WHP 1000 heating plate
is used as a bottom heater in a 3-step temperature-time
profile.

Technical data

Dimensions: 

254 x 280 x 70 mm

(W x L x H)

10 x 10 x 2,75 inch

Heating plate:

150 x 220 mm
6 x 8,7 inch

Mains voltage: 

230 V (120 V); 50 Hz (60 Hz)

Power: 1000 

Temperature range: 

50°C - 300°C (150°F - 570°F)

Protection class: 

1

3. Placing in operation

Remove all temperature sensitive and flammable objects
from the vicinity of the heating plate. Ensure that the heating
plate is switched off. 

Ensure that the mains voltage is correct. Connect the device
to the mains (11). Switch on the device at the mains switch
(5). When the device is switched on, a self-test is performed
during which all display elements (3) are operated. The 
temperature set (setpoint) and the temperature scale (°C /
°F) are then displayed briefly. The display then switches
automatically to the indication of the actual value. The red
dot on the display illuminates (7). This dot is a visual 
indication of the state of the regulation.
Continuous illumination indicates the system is warming up.
Flashing indicates that the operating temperature has been
reached. The colour of the heated surface can change when
heated for the first time.

3.1. Adjusting temperature

The digital display (3) normally indicates the actual 
temperature. The digital display (3) switches to the current
setpoint when the ”

UP

” or “

DOWN

” button (4) (6) is pressed.

The setpoint (flashing indication) can now be changed as
required by pressing or pressing and holding the ”

UP

” or

DOWN

” button (4) (6). If the button is pressed and held

down, the setpoint changes quickly. Approx. 2 sec. after the
button is released, the digital display (3) automatically 
switches back to the actual value.

3.2. Manual heating shut down (OFF)

The device heating is shut down by simultaneously pressing
the ”

UP

” and “

DOWN

” buttons. "

OFF

" appears on the

display (3). If the standby function is also active, the 
temperature is reduced to 65°C (150°F). “

Stb

” appears on

the display (3).

3.3. Adjust Temperature-OFFSET

The real surface temperature can be readjusted in a
± 40°C (± 72°F) OFFSET range.
1. Press key for special function (8). Display (3) show 

000

2. Set Auto-OFFSET-temperature value with key ”

UP

” or

DOWN

”. After 4 sec. the Display switch back to actual

value.

3.4. Automatic heating shut down (AUTO OFF function)

The auto off time for the heating shut down is displayed 
flashing by pressing and holding (approx. 3 sec.) the key for
special function (8). The shut-down time can be adjusted in
5 minute steps in the range 5 - 600 min by pressing the

UP

” or “

DOWN

” button (4) (6). A setting of less than 5 min 

switches off the automatic heating shut-down and "

OFF

"

appears on the display (4).

If the standby function is also active, the temperature is
reduced to 65°C (150°F). “

Stb

” appears on the display (3).

3.5. Operation using RS232 serial interface  

When operated together with the WHA 3000P / WHA 3000V
hot air station, the WHP 1000 heating plate is controlled via 

9

English

www.

.com

[email protected]

1.800.561.8187

Содержание WHP 1000

Страница 1: ...ingsvejledning Manual do utilizador Käyttöohjeet ËÁ Â ÂÈÙÔ ÚÁ Kullan m k lavuzu Návod k pouÏití Instrukcja obs ugi Üzemeltetési utasítás Návod na pouÏívanie Navodila za uporabo Kasutusjuhend Naudojimo instrukcija Lieto anas instrukcija Ръководство за работа Manual de exploatare Naputak za rukovanje www com information itm com 1 800 561 8187 ...

Страница 2: ...r 12 5 Felindikering på displayen 12 6 Andra Power On rutiner 12 7 Tillbehör 8 Leveransomfattning 12 Índice Página 1 Atención 13 2 Descripción Datos técnicos 13 3 Puesta en servicio 13 4 Servicio con sensor externo 13 5 Indicación de fallos en la pantalla 14 6 Otras rutinas Power On 14 7 Accesorios 8 Volumen de suministro 14 Indholdsfortegnelse Side 1 Bemærk 15 2 Beskrivelse Tekniske data 15 3 Ibr...

Страница 3: ...e 5 Netzschalter 6 DOWN Taste 7 Optische Regelkontrolle 8 Spezialtaste für Sonderfunktionen 9 Externer Sensor 10 RS232 Schnittstelle externe Ansteuerung 11 Netzanschluss 1 LED Remote externe aansturing RS232 2 Indicatie externe sensorregeling 3 Display 3 cijferig 7 segmentdisplay 4 UP toets 5 Netspanningschakelaar 6 DOWN toets 7 Optische regelcontrole 8 Speciale toets voor speciale functies 9 Exte...

Страница 4: ...st Offset Manual heating shut down Off Automatic heating shut down Auto Off or minutes Key function via Power On Routine Standby function ON OFF 1 ON oder 0 OFF Change over C F C or F Resetting to the factory setting FSE OFF FSE I OFF 3 sec www com information itm com 1 800 561 8187 ...

Страница 5: ...all display elements 3 are operated The temperature set setpoint and the temperature scale C F are then displayed briefly The display then switches automatically to the indication of the actual value The red dot on the display illuminates 7 This dot is a visual indication of the state of the regulation Continuous illumination indicates the system is warming up Flashing indicates that the operating...

Страница 6: ...heating lamps The external sensor an insulated thermocouple type K is connected to socket 9 LED 2 on the display 3 illuminates Note The sensor must be adequately in contact with the assembly or component for correct operation When working with the external sensor the temperature setting setpoint must be adjusted to suit the measuring point 5 Error indications on the display 3 No temperature sensor...

Страница 7: ...47 Circuit Diagram www com information itm com 1 800 561 8187 ...

Страница 8: ...48 Exploded Drawing www com information itm com 1 800 561 8187 ...

Страница 9: ...Weller is a registered Trademark and registered Design of Apex Tool Group LLC 2014 Apex Tool Group LLC T005 57 172 06 12 2014 T005 57 172 04 10 2012 www com information itm com 1 800 561 8187 ...

Отзывы: