3.

 

Periodic cleaning method 
Unscrew the nozzle, the nozzle should be washed with clean water, clean nozzle holes to 
remove all collected dirt, use fine wire to remove stubborn residue, as shown in diagram. 
With strainer tap (under inflow model) according to the diagram 3 shows, remove the inlet 
strainer on the basis and clean as in section 2 to keep performance. 
Then install it as before. Strainer according to the chart 4 shows, remove the inlet strainer 
for cleaning, then according to the diagram 4 Reinstall. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Troubleshooting 

 
 

Fault 

Failure Cause 

Solution 

Water Not Heating  No plugged or hydraulic pressure too low  Check the power supply circuit wire is connected 

and the minimum use water pressure not less than 
0.04MPa 

Low Water / High 
Temperature 

Too much water or the voltage is to low  Decrease water pressure, check the power supply 

and use of voltage 

Water Outlet Low  Water inlet blocked or hydraulic pressure 

too low 

Check inlet filter for dirt and remove it and then 
increase water inlet flow and pressure to low. 

No Indicator Light  Hydraulic pressure is too low, can’t open 

power supply or circuit fault 

Use the water heater when the hydraulic pressure 
is normal level. 

Содержание INSTANT HEATING

Страница 1: ...ION MANUAL INSTANT HEATING ELECTRIC FAUCET Thank you for choosing WELL Please read carefully the following instructions and keep them within reach Reorder No FCT EL BILLABONG WL FCT EL CREEK WL FCT EL STREAM WL ...

Страница 2: ...a hazard 7 Working water pressure 0 04 0 6 MPa 8 The appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction 9 Children being supervised not to play with the appliance 10 The water inlet of this appliance shall not be connected to inlet water obtained fr...

Страница 3: ...manent damage to your water heater faucet Do not switch on until faucet has been flushed and connected correctly 9 Must be connected to main water or pressure hose to avoid damage to heating coil 10 Before installation please confirm that the power supply is switch off heat master is in off position correct leakage protector is being used 11 Heat Master must be connected according to the wiring di...

Страница 4: ...ofessional person selecting a suitable tool Water heater need appropriative power wire It is forbidden to share with another power wire Please attention to cable coloring live L brown neutral N blue connection wiring E yellow blue 4 Pull handle left rotation to hot water position heating lamp indicator lights and heating starts rotate handle right for cold water position heating lamp will switch o...

Страница 5: ... diagram 4 Reinstall Troubleshooting Fault Failure Cause Solution Water Not Heating No plugged or hydraulic pressure too low Check the power supply circuit wire is connected and the minimum use water pressure not less than 0 04MPa Low Water High Temperature Too much water or the voltage is to low Decrease water pressure check the power supply and use of voltage Water Outlet Low Water inlet blocked...

Страница 6: ...d are harmful to health Submitting waste electrical and electronic equipment to special collection centers makes the waste to be recycled properly and protecting the environment Do not forget Each electric appliance that arrives at the landfill the field pollutes the environment Importer distributor SC VITACOM ELECTRONICS SRL CIF RO 214527 Tel 0264 438401 sales vitacom ro www vitacom ro ...

Отзывы: