Completing Installation
34.
Once the inFlow™ ACE is inserted and secured, use ¼" tubing to connect from the sample outlet to an appropriate
customer-supplied sample container, such as a Welker TCC Transportable Crude Oil Container.
Customer-supplied ¼" tubing must slope downward from the inFlow™ ACE to the sample container.
35.
Use appropriately sized tubing to connect from the normally open port on the solenoid to port A on the motor housing
(
). Use appropriately sized tubing to connect from the normally closed port on the solenoid to port B on the
motor housing (
).
The normally open port should be stamped "A" or "NO."
The normally closed port should be stamped "B" or "NC."
36.
Open emergency shutoff valve E (
).
37.
As necessary, adjust the external sand relief. With emergency shutoff valve E open, loosen the jam nut, tighten the
adjusting screw on the external sand relief, and then tighten the jam nut as a locking device (
).
After the external sand relief valve has been set, emergency shutoff valve E must remain open during sampling. For more
information about emergency shutoff valve E, see
Section 2.7, Emergency Shutoff
.
The external sand relief comes factory-set by the manufacturer if requested at the time of order.
15
IOM-161
MODEL: INFLOW™ ACE WITH AI CONTROL™
REV: D
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331