Lp. 

Description 

front view 

Multifunction knob (selection and adjustment of parameters) 2 
control parameters MMA HOT START (1-10) and ARC FORCE (1-10) 3 
display 4 
Power LED 5 
overload indicator light (alarm) 6 
carrying handle (shoulder strap) 7 
mode switch; MMA MMA welding GAS: free 
flow of gas (test gas)

4T LIFT: TIG mode selection handle 4-stroke at the pole arc is struck (LIFT) 2T LIFT: TIG mode selection handle 

2-stroke at the pole arc is struck (LIFT) 4T HF TIG mode selection handle 4T at a non-contact arc is struck (HF) 2T HF 
TIG mode selection handle 2T with a non-contact arc is struck (HF) 8 

control parameters and TIG TIG PULS 9 
slot of positive polarity (MMA handle, a ground terminal TIG) 10 
control socket TIG 5-pin of the protective cap 11 
cavity of negative polarity (ground terminal MMA TIG) 12 
Gas socket (quick type 21) 

rear view 

13, the input power cord 230V / 50Hz main switch 14 ON / OFF 
15 

Protective gas connection (plug for quick coupling type 21) 

V. INSTALLATION 

V. INSTALLATION 

WORKING ENVIRONMENT 

Welder set equal to (maximum angle of inclination of 15 °) and dry surface with a capacity suitable for the weight in order to avoid its overturning. 

The device should be placed in a well ventilated area with free air circulation, away from flammable objects (min. Distance from other objects 0.5m). Make sure 
not enter the welder dust, corrosive vapors and moisture.

The unit should be set in such a place, not to get into it from welding spatter. 

CONNECTING TO NETWORK 

Before the electrical connection:

check whether the data on the plate correspond to the values ​​of the welding voltage and frequency of the network devices in the workplace 

check that the mains supply for the required input power 

check whether the fuse values ​​are consistent with those given in the technical data 

Check the wiring grounding welding. Welding wire is supplied with a 230V plug.

ELECTRICAL CONNECTION SHOULD BE CARRIED OUT BY QUALIFIED PERSONNEL OR EXPERIENCED

PREPARATION TO WORK: 

1) Before connecting the welder to the mains, make sure that the main switch (rear panel) is in the off position 

1) Before connecting the welder to the mains, make sure that the main switch (rear panel) is in the off position 
2) Hollow clamp the wire mass to secure the work piece 

2) Hollow clamp the wire mass to secure the work piece 
3) The other end of the cable plugs into the mass of positive polarity (+) - TIG, or slot 

3) The other end of the cable plugs into the mass of positive polarity (+) - TIG, or slot 

of negative polarity (-) - method MMA 

4) Plug the operating handle connected to the outlet of the negative polarity (-) - TIG, or slot 

4) Plug the operating handle connected to the outlet of the negative polarity (-) - TIG, or slot 

of positive polarity (+) - method MMA 

5) To the output gas (front panel) connect the plug of the gas holder 

5) To the output gas (front panel) connect the plug of the gas holder 

(TIG only) 

6) The slot-pin controller 5 (front panel) to connect the plug of the control handle 

6) The slot-pin controller 5 (front panel) to connect the plug of the control handle 

TIG welding (TIG only) 

Содержание POWER DC TIG 200

Страница 1: ...or loosened connections 4 Do not use cables with damaged insulation work and or loosened connections 5 Make sure that the power cord is not damaged 5 Make sure that the power cord is not damaged 6 Do...

Страница 2: ...re that the welding work is adequate ventilation and that there are appropriate measures to 3 Make sure that the welding work is adequate ventilation and that there are appropriate measures to removal...

Страница 3: ...FAN INSULATION CLASS IP23 DEGREE OF PROTECTION F DIMENSIONS 43x14x25cm WEIGHT 7 5 kg Duty cycle is based on the percentage distribution of 10 minutes for the time in which the machine can weld at rate...

Страница 4: ...place not to get into it from welding spatter CONNECTING TO NETWORK Before the electrical connection check whether the data on the plate correspond to the values of the welding voltage and frequency...

Страница 5: ...l operator preferences set the operating parameters The mode switch to select the mode flare holder 2 stroke or 4 stroke and arc ignition way contact contactless HF LIFT To access the settings menu of...

Страница 6: ...st before switching off MMA After selecting switch methods of work 7 MMA the operator can set three operating parameters welding current turning multipurpose knob and the value HOT START ARC FORCE To...

Страница 7: ...trode diameter mm 6 4 0 5 8 1 0 9 5 1 6 or 2 4 11 1 3 2 selected plant res ratio of the diameter of the gas nozzle to cupcake and the flow of shielding gas selected plant res ratio of the diameter of...

Страница 8: ...s only valid if accompanied by a receipt or purchase invoice Difficulties arising from misuse negligence or breach of the device are not covered by the warranty The manufacturer is not liable for any...

Отзывы: