42
Smear of oil.
→
One-way valve is leaky.
→
Connection
base
chimney-telescopic
chimney is leaky.
→
Seal the valve.
→
Seal the connection with a
suitable material.
Appliance vibrates.
→
The motor is not properly
fixed.
→
The hood is not properly
fixed.
→
Fix the motor properly.
→
Fix the hood properly.
Insufficient extracting capacity.
→
Too much distance hood-
hob
→
Too
much
draught
because of open doors
and/or windows
→
Lower position of hood
→
Close the doors/windows
Appliance is unstable.
→
Mounting rail is not firmly
fixed.
→
The screws are not firmly
tightened.
→
Fix the mounting rail
properly
→
Tighten the screws
If the appliance has a malfunction not noted on the schedule or if
you have checked all items on the schedule but the problem still
exists, please contact the shop you purchased the appliance at.
If the hood does not work properly and/or you can hear
increased operating noise, check the schedule below:
(1)
incorrect dimension of the air duct.
(2)
obstruction in the air duct.
(3)
the diameter of the air duct from hood to wall-box inclusive
should be 120 mm; otherwise the capacity of the motor may
be decreased.
(4)
if you have installed a fly screen on the wall-box, the air vent
may be obstructed. Check by removing the fly screen.
(5)
if the cover panel of the wall box is equipped with firm and
slanted slats, the air vent may be obstructed. Check by
removing the cover panel.
(6)
install a cover panel with moveable slats, which do not
obstruct the air vent.
(7)
check condition and cleanliness of the filters.
(8)
check if the air which is extracted by the hood is replaced to
avoid negative pressure.
(9)
when you run your appliance in recirculating mode, check if
the carbon filter has been replaced on time (min. every 3-6
months).