background image

2

Do not attempt to disassemble or modify the battery pack. There are
no user serviceable parts inside pack.

Do not attempt to directly solder to the battery pack.

Do not attempt to connect the positive and negative battery terminals
to each other, nor to any other device.

“Caution” - use of controls or adjustments or performance of
procedures other than those specified herein may result in hazardous
radiation exposure.

Do not operate, charge, leave or discard battery pack in any
environment where it may exceed 0°C to 40°C.

Do not immerse the battery pack in water.

Do not attempt to open or pierce the battery pack.

Do not strike or throw the battery pack.

Do not use a battery pack which appears to be deformed, leaking,
corroded, or is otherwise irregular.

If electrolyte leaking from battery contacts your skin or eyes, rinse
with running water and immediately seek medical attention.

IPXØ: Not protected against the ingress of water.

Not for use in the presence of flammable anesthetics.

Содержание SureSight

Страница 1: ...4341 State Street Road Skaneateles Falls NY 13153 0220 140400 1 Rev A...

Страница 2: ......

Страница 3: ...13 Battery 13 Plus or Minus Cylinder Convention 14 Diopter Power Resolution 14 Controls 15 Operating Instructions 16 Important Operating Tips 18 Helpful hints for testing pre schoolers 18 Results 19 A...

Страница 4: ...t Software 22 Hand Strap Replacement 23 Cleaning and Sterilization of the SureSight 23 Service Calibration and Warranty Information 24 Warranty 24 Service and Warranty 25 SureSight Rechargeable Batter...

Страница 5: ...replacement parts and accessories specified in this manual Refer to the maintenance section of this manual for more information Do not sterilize the instrument or any of its components Use only with I...

Страница 6: ...azardous radiation exposure Do not operate charge leave or discard battery pack in any environment where it may exceed 0 C to 40 C Do not immerse the battery pack in water Do not attempt to open or pi...

Страница 7: ...ed UL2601 1 CSA C22 2 No 601 1 IEC 60601 1 AS 3200 1 IEC 60601 1 2 Australia EMC Framework Compliance The CE mark on this device indicates that it has been tested and conforms to the provisions noted...

Страница 8: ...res de rechange Utiliser uniquement les pi ces et accessoires de rechange autoris s sp cifi s dans ce manuel Consulter la section Entretien de ce manuel pour des informations suppl mentaires Ne pas st...

Страница 9: ...d autres dispositifs Attention Des proc dures de contr le de r glage ou de performance autres que celles qui sont sp cifi es dans cette notice peuvent entra ner une exposition dangereuse au rayonneme...

Страница 10: ...Ne pas utiliser en pr sence d anesth siques inflammables Equipement de type BF Double isolation Homologations ETL UL 2601 1 CSA C22 2 No 601 1 et IEC 60601 1 AS3200 1 IEC 60601 1 2 Obedece la norma a...

Страница 11: ...erence and should not present problems to other equipment or be affected by other devices As a precaution avoid using this device in close proximity to other equipment Note This product contains no ha...

Страница 12: ...umber of and variation among measurements for the given eye Diopter display 1 8 or 1 4 diopter increments Axis 1 increments Stand Compact charger and SureSight storage Weight Approximately 2 0 lbs 0 9...

Страница 13: ...1 1996 pending Patents US 6 007 204 and Des 413 979 International Patents Pending Office illumination Not for use in direct sunlight Indoor operation only Materials This product is latex free Electrom...

Страница 14: ...nytime anywhere Carry it from room to room to your waiting area even off site SureSight solves many of the problems you face when performing exams You can perform objective refraction from a non threa...

Страница 15: ...Features Right eye field Sphere Cylinder Axis Clear results and Child adult calibration Peephole with crosshair target for aiming Reliability measure Left eye field Print and left right toggle Start...

Страница 16: ...12 Charging Jack Receptacle Receptacle for RS232 Connection Battery Compartment Fixation LEDs Distance Sensor IR link to printer...

Страница 17: ...icated by the arrow and lifting out 2 Insert the new battery into the compartment in the direction of the arrow on the battery itself so that the terminal end enters the compartment first If necessary...

Страница 18: ...he first switch located on the side of the unit with the handstrap up towards the bottom of the SureSight Diopter Power Resolution Your SureSight was set at the factory to display power in 1 4 diopter...

Страница 19: ...will bring up results Child Adult Calibration Clears readings Changes child adult Calibration by holding it down Left Right Toggle Print Selects single eye to re test or switches back to regular test...

Страница 20: ...will hear slow low pitched beeps Slowly move closer When the unit is at the correct distance 14 you will hear a steady low tone When the unit is too close you will hear quick high pitched beeps The c...

Страница 21: ...the patient s eyelids are not occluding the pupil aim higher when over refracting through glasses To stop a test at any time hold any button until 5 tones sound When the unit is off any button wakes...

Страница 22: ...tance Not Taking Readings Are you square and level Scan around the pupil Ask patient if they see the red light When over refracting through glasses aim higher Helpful hints for testing pre schoolers H...

Страница 23: ...on of the test is necessary If the patient did not appear to fixate on the unit during data acquisition repeat the test even if reliability numbers are 6 S is the sphere in diopters C is the cylinder...

Страница 24: ...n the battery cover located on the underside of the unit by sliding it in the direction indicated by the arrow and lifting out 2 Rotate the lever holding the battery in clockwise direction until the b...

Страница 25: ...To prolong on time press three buttons simultaneously to shut down Recycling Lithium Ion Battery Welch Allyn now employs the services of an agency which can disassemble and recycle all components of...

Страница 26: ...lever holding the battery in and lift the battery from its compartment 3 View the DIP switches inside the battery compartment located on the button side of the unit Using tweezers or another appropria...

Страница 27: ...erly Cleaning and Sterilization of the SureSight NOTE Excess solution entering the assembly could damage internal components Use caution to ensure cloth is not saturated with solution Cleaning solutio...

Страница 28: ...o cost to the purchaser This warranty only applies to instruments purchased new from Welch Allyn or its authorized distributors or representatives The purchaser must return the instrument directly to...

Страница 29: ...Ion batteries are warranted by Welch Allyn for two years from date of manufacture when used in Welch Allyn instruments only Defective batteries will be replaced on a pro rata basis should failure occ...

Страница 30: ...26...

Страница 31: ......

Страница 32: ...4341 State Street Road Skaneateles Falls NY 13153 0220...

Отзывы: