Disclaimer

The Information in this guide has been carefully checked for reliability; however no guarantee is given as to the correctness of the
contents and WELCH ALLYN SCHILLER makes no representations or warranties regarding the contents of this manual. We reserve
the right to revise this document and make changes in the specification of the product described within at any time without obligation
to notify any person of such revision or change.

Trademarks

WELCH ALLYN SCHILLER and AT-2

plus

 are registered trademarks of WELCH ALLYN SCHILLER. All trademarks are the

property of their owners.

Copyright Notice

© Copyright 1999 by WELCH ALLYN SCHILLER. All rights reserved. You may not reproduce, transmit, transcribe, store in a
retrieval system or translate into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical,
manual or otherwise, any part of this publication without express written permission of WELCH ALLYN SCHILLER.

Terms of Warranty

WELCH ALLYN SCHILLER warrants the AT-2

plus

 Electrocardiograph, when new, to be free of defects in material and workmanship

and to perform in accordance with manufacturer`s specifications for the period of three (3) years from the date of purchase from
Welch Allyn or it`s authorized distributors or agents. Accessory items such as electrodes, batteries and cables are limited to a
warranty of 90 days from the date of purchase from Welch Allyn or its authorized distributors or agents. Welch Allyn will repair
or replace any components found to be defective or at variance from manufacturer`s specifications within this time at no cost to the
customer. It shall be the purchasers responsibility to return the instrument to Welch Allyn or an authorized distributer, agent or service
representative. This warranty does not include breakage or failure due to tampering, misuse, neglect, accidents, modifications or
shipping. This warranty is also void if the instrument is not used in accordance with manufacturer`s recommendations or if repaired
by other than Welch Allyn or an authorized agent. Purchase date determines warranty requirements. No other express warranty
is given.

Disclaimer

The Information in this guide has been carefully checked for reliability; however no guarantee is given as to the correctness of the
contents and WELCH ALLYN SCHILLER makes no representations or warranties regarding the contents of this manual. We reserve
the right to revise this document and make changes in the specification of the product described within at any time without obligation
to notify any person of such revision or change.

Trademarks

WELCH ALLYN SCHILLER and AT-2

plus

 are registered trademarks of WELCH ALLYN SCHILLER. All trademarks are the

property of their owners.

Copyright Notice

© Copyright 1999 by WELCH ALLYN SCHILLER. All rights reserved. You may not reproduce, transmit, transcribe, store in a
retrieval system or translate into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical,
manual or otherwise, any part of this publication without express written permission of WELCH ALLYN SCHILLER.

Terms of Warranty

WELCH ALLYN SCHILLER warrants the AT-2

plus

 Electrocardiograph, when new, to be free of defects in material and workmanship

and to perform in accordance with manufacturer`s specifications for the period of three (3) years from the date of purchase from
Welch Allyn or it`s authorized distributors or agents. Accessory items such as electrodes, batteries and cables are limited to a
warranty of 90 days from the date of purchase from Welch Allyn or its authorized distributors or agents. Welch Allyn will repair
or replace any components found to be defective or at variance from manufacturer`s specifications within this time at no cost to the
customer. It shall be the purchasers responsibility to return the instrument to Welch Allyn or an authorized distributer, agent or service
representative. This warranty does not include breakage or failure due to tampering, misuse, neglect, accidents, modifications or
shipping. This warranty is also void if the instrument is not used in accordance with manufacturer`s recommendations or if repaired
by other than Welch Allyn or an authorized agent. Purchase date determines warranty requirements. No other express warranty
is given.

Содержание Schiller AT-2plus

Страница 1: ...i i AT 2plus Spiro Option AT 2plus Spiro Option Schiller Menu Manuals...

Страница 2: ...296 682 140 Tel 800 561 8797 Fax 01296 682 104 Fax 905 890 0008 Copyright 1999 by Welch Allyn Schiller AT 2plus Spiro Option User Guide Article Number 2 510339wa Welch Allyn Inc 7420 Carroll Road San...

Страница 3: ...r an authorized agent Purchase date determines warranty requirements No other express warranty is given Disclaimer The Information in this guide has been carefully checked for reliability however no g...

Страница 4: ...o Schiller AG for disposal Alternatively dispose of the unit in municipally approved recycling centres This equipment has been tested and found to comply with the limits for a class A digital device p...

Страница 5: ...ns connector on the back panel Remove the fuse panel and replace the fuse s Click back the fuse panel Power Supply The mains connection is on the rear of the unit The power supply voltage is set by th...

Страница 6: ...IF INDICATED FEDERAL LAW IN THE USA RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN PHYSICIAN S RESPONSIBILITY THE AT 2PLUS AND THE SP 250 SENSOR ARE PROVIDED FOR THE EXCLUSIVE USE OF...

Страница 7: ...USE TO ELIMINATE THE DANGER OF CROSS CONTAMINATION DO NOT USE THE MOUTHPIECE FOR MORE THAN ONE PATIENT Safety Notices TO PREVENT ELECTRIC SHOCK DO NOT DISASSEMBLE THE UNIT NO SERVICEABLE PARTS INSIDE...

Страница 8: ...ation is excluded from this guide except where necessary to operate the unit or understand the results Intended Use TheAT 2plus and the SP 250 sensor can be used to measure Forced Vital Capacity FVC F...

Страница 9: ...ix ix...

Страница 10: ...x x...

Страница 11: ...TECHNICAL DATA 48 ACCESSORIES ORDERING 49 SPIROMETRY TIPS HOW TO DO IT AND COMMON PITFALLS AND PROBLEMS How to Do It 50 FVC 51 FEV1 52 Patient Related Problems 53 INDEX 54 Contents CONTENTS 1 INTRODUC...

Страница 12: ...ntains a sensitive measuring device and must always be handled with care Do not allow the sensor to be dropped or subjected to any sudden blows Introduction The Spirometry function of the SCHILLERAT 2...

Страница 13: ...e 3 Press the Patient key and enter patient data see page 11 4 PresstheALT Key to display the menu options The pulmonary menu is displayed SP 250 ALT C ECG ALT P SPIRO ALT Procedure Overview WARNING F...

Страница 14: ...test Key 3 3 AUTO MVVtest Key 4 4 5 MV test Key 6 6 20 Results Key 7 7 5 10 Pre Post Key 8 8 25 Calibration Key 0 0 1mV Settings M Memory C ECG Procedure Overview Key 1 1 FVCtest Key 2 2 SVC test Key...

Страница 15: ...ibrated At the beginning of each day If the sensor is changed When a significant temperature or pressure difference occurs The calibration procedure is detailed on page 21 Procedure Overview 5 If usin...

Страница 16: ...n litres being represented on the vertical axis and the time in seconds on the horizontal axis ALSO SEE SPIROMETRY TIPS AT THE END OF THIS BOOK Procedure Overview 8 Select test Forced Vital Capacity F...

Страница 17: ...t should breathe normally 3 times and then inhale maximally to total lung capacity and then expire maximally Make sure that the patient understands what is required of him Procedure Overview MVV Test...

Страница 18: ...e lowest FVC FEV1 value of the tests already made and stored will be overwritten NOTE The marked results correspond to the displayed test curve Procedure Overview 9 Click the Auto START key The flow s...

Страница 19: ...nd post and the percentage change i e difference between pre and post medication results The diagnosis resulting from the premedication test is also given on this printout Procedure Overview 11 Repeat...

Страница 20: ...or all parameters except the following which are based solely on the highest FVC FEV1 value FEF0 2 1 2 FEF25 75 FEF75 85 FEF25 FEF50 FEF75 FIF50 Definition of Best In accordance with the ATS Spirometr...

Страница 21: ...tients race W B W for White B for Black all languages except American see page 20 C H B A C for Caucasian H for Hispanic B for Black or A forAsian American only see page 20 Entering Patient Data Each...

Страница 22: ...d value This can account for a possible variation Where a difference exists the values given on the printout are always the more accurate Displaying the Results in Tabular Form Press the Results optio...

Страница 23: ...532 129 FEV 1 FVC 8 23 9 36 114 FEF 2 1 2 l s FEF 25 75 l s FEF 75 85 l s PEF l s FEF 25 l s FEF 50 l s FEF 75 l s FMFT s FIVC l FIV1 l FIV1 FIVC FIV1 FVC PIF l s FIF50 l s Displaying the Results in T...

Страница 24: ...e given formulas The 85 race compensation is calculated only when the following normal values are selected COMPOSITE KNUDSON CRAPO MORRIS POLGAR Race Influences on Norm Values According to the setting...

Страница 25: ...f last calibration The diagnostic statement if enabled in Settings menu The MTAidentification The user identification The date and time of the printout The software version Printout Click the PRINT co...

Страница 26: ...s 1 Time Scale 20mm s 2 Flow graph on printed 3 Flow graph off 4 Volume graph on printed 5 Volume graph off 6 Curve Format Best 7 CurveFormatAll Spiro Settings This menu option defines all the general...

Страница 27: ...on diagnosis printed 1 Diagnosis off diagnosis not printed 2 PEF l m Peak Expiratory flow calculation litres minute 3 PEF l s Peak Expiratory flow calculation litres second Spiro Settings Flow Graph V...

Страница 28: ...und Quanjer 9 Finnish Quanjer ALT 0 1mV 0 1mV 0 1mV 5 10 0 Indian DIAGNOSISACCORDINGTO ITS RECOMMENDATIONSISAVAILABLEWHENAMERICANISSET SEEPAGE20 Spiro Settings Normals The Normal value standards are g...

Страница 29: ...LT 0 1mV 0 1mV 0 1mV 7 5 10 0 Measurement type Vol f t 1 Measurement type Flow f Vol 2 Flow loop 4 Report Type Best 5 Report Type Measurement 1 Flow f t Flow f vol Flow loop Spiro Settings Measurement...

Страница 30: ...uage is Standard English Define American or Standard English as follows ALT 0 1mV 2 5 10 For American English ALT 0 1mV 2 2 For Standard English Spiro Settings American and Standard English The unit l...

Страница 31: ...key 8 The following screen is displayed ALT then 8 25 Last calib 25 03 99 BTPS Factor 1 090 Calib Factor 1 002 Temperature 21 o C Measured volume 0 00 l Syringe Vol 6 00 l Calibration To calibrate pr...

Страница 32: ...sensor e g pumping 2 litres 3 times amounts to 6 litres the recommended volume with a 2 litre pump is 4 litres and with a 3 litre pump 6 litres Calibration LastCalibration date of last calibration BT...

Страница 33: ...and I before recalibrating Click the PRINT copy key to obtain a printout of the calibration report with measurement details time and date of calibration andagraphoftheflow Calibration CalibrationProc...

Страница 34: ...of the forced vital capacity FVC MEF25 flow speed of the expired air by 75 of the forced vital capacity FVC MEF75 FEF25 MEF50 FEF50 MEF25 FEF75 Explanation of Measured Values FVC Forced expiratory Vi...

Страница 35: ...imum inspiratory flow speed in litres second MIF Maximum Inspiratory Flow Maximum inspiratory flow in litres MIF50 flow speed by 50 of the forced inspiratory vital capacity Explanation of Measured Val...

Страница 36: ...Condition 80 70 Restrictive 80 Obstructive 70 Combined 80 70 The measurement FEV1 FVC or FEV1 VC will adapted on the screen and on the printout Diagnosis The diagnostic interpretation is dependent up...

Страница 37: ...f LLN Severe Obstruction FEV1 FVC is 40 of LLN Mild Restriction FVCpredicted is 60 to 80 Moderate Restriction FVCpredicted is 50 to 60 Severe Restriction FVCpredicted is 50 Diagnosis Diagnosis Setting...

Страница 38: ...ing pages IMPORTANT Due to great differences in the size of the lungs of children there are no standard values for children under 6 years of age Norm Values The norm values used for the calculation of...

Страница 39: ...0 470 3 218 x H 0 025 x A 1 596 MEF50 3 794 x H 0 031 x A 0 352 2 450 x H 0 025 x A 1 156 MEF25 2 605 x H 0 026 x A 1 336 1 050 x H 0 025 x A 1 107 H Height in meters A Age Norm Values Norm Values for...

Страница 40: ...2 7 0 95 x H2 7 FEV1 0 84 x H2 7 0 81 x H2 7 FEV1 SVC 0 84 0 84 MEF PEF 8 2 x H 6 8 6 6 x H 5 3 MEF50 5 6 x H 4 4 4 6 x H 3 3 H Height in meters Norm Values Quanjer Tammeling Comparisons The Quanjer a...

Страница 41: ...09Fi PEF25 1 372 0 938In H 0 0152A 0 000036A 2 FEV1 FVC 92 33 FEV1 FVC 118 993 3 0320H 2 6 9053In A H Height in meters A Age in years W Weight in kg Fi Body fat index H 3 W Norm Values Austrian Standa...

Страница 42: ...9 4 81 x H 0 020 x A 2 81 1 09 4 04 x H 0 022 x A 2 35 FEV 1 01 09 3 44 x H 0 033 x A 1 00 1 09 2 67 x H 0 027 x A 0 54 A Age H Height in meters Norm Values Swedish Standards Berglund The Swedish Berg...

Страница 43: ...33 H 2 1533 FEV1 FVC exp 0 00062 x A 0 1586 x log A 0 0853 H 2 0975 PEF l s exp 0 00677 x A 0 4017 x log A 0 7422 H 0 9661 A Age H Height in meters log Logarithm to base 10 Norm Values FinnishStandard...

Страница 44: ...0088 x H 0 0301 x A 1 0402 0 0113 x H 0 0288 x A 0 5012 MVV 1 3056 x H 0 5228 x A 93 2102 0 7149 x H 0 3624 x A 25 0208 A Age H Height in meters Norm Values IndianEquations The Indian equations are va...

Страница 45: ...0271 x A 3 512 0 1123 x H 0 0257 x A 2 745 FEV3 FVC 0 1593 x H 0 1450 x A 112 090 0 2380 x H 0 1630 x A 118 160 MVV 3 4040 x H 1 2600 x A 21 400 2 0500 x H 0 5700 x A 5 500 Norm Values for USA and Can...

Страница 46: ...1 x H 0 0152 x A 1 914 0 0605 x H 0 0185 x A 0 809 FEV3 FVC 0 1593 x H 0 1450 x A 112 090 0 2380 x H 0 1630 x A 118 160 A Age H Height in inches Norm Values for USA and Canada Crapo Norm Values The Cr...

Страница 47: ...0 3 x H2 85 SD 14 PEFR l min 7 69 x 10 4 x H2 63 SD 17 PEF l min 6 97 x 10 4 x H2 64 SD 18 FEF25 75 l min 9 13 x 10 4 x H2 45 SD 25 FEF25 75 l min 1 20 x 10 3 x H2 40 SD 24 Norm Values for USA and Can...

Страница 48: ...1400 x H 0 6850 x A 4 870 In addition there are the following ITS equations FEV3 FVC 0 1593 x H 0 1450 x A 112 090 0 2380 x H 0 1630 x A 118 160 Norm Values for USA and Canada Knudson Norm Values The...

Страница 49: ...64 0 2819 x H 0 109 x A 107 38 FEF25 75 0 1143 x H 0 031 x A 1 864 0 0533 x H 0 024 x A 1 171 PEF 0 2388 x H 0 035 x A 5 993 0 1245 x H 0 025 x A 0 735 FEF25 0 2235 x H 0 035 x A 5 618 0 1092 x H 0 02...

Страница 50: ...Value Equation Reference FVC Knudson FEV1 Knudson FEV3 Crapo FEF25 75 Knudson FEF75 85 Morris FEF 2 1 2 Morris MVV Crapo SVC Knudson same as FVC Norm Values Composite Norm Values Selection of the Comp...

Страница 51: ...0690 A 0 0190 2 147 FEF50 H 0 1737 A 0 0366 5 409 H 0 0681 A 0 0289 0 609 FEF75 H 0 0787 A 0 0230 2 483 H 0 0244 A 0 0259 1 118 MVV H 3 03 A 0 816 37 9 H 2 14 A 0 685 4 87 Norm Values Polgar Norm Val...

Страница 52: ...AT 2plus User Guide Spirometry Supplement Page 42 AT 2plus Spirometry Supplement Page 42 Changing the Flow Sensor SP 250 RS 232 Changing the Flow Sensor SP 250 RS 232...

Страница 53: ...nsure that the orientation is correct by checking the guide protrusion in sensor against the guide slot in the handle 4 Calibrate the sensor and unit as detailed on page 23 Changing the Flow Sensor SP...

Страница 54: ...601 1 Calibration of the sensor as detailed on page 23 The test results must be documented Lifed Items There are no lifed items in the AT 2plus Care Maintenance Self test Initiate a self test of the...

Страница 55: ...able can be wiped with soapy water Sterilization if required should be done with gas only and not with steam To disinfect wipe the cable with hospital standard disinfectant Care Maintenance WARNINGS O...

Страница 56: ...immediately If no paper is left the printing process is interrupted and a warning is given on the screen To replace the paper proceed as follows Replacing the Recording Paper The recording paper must...

Страница 57: ...e g sterilisation liquids 4 In particular do not store in a plastic cover 5 Certain glues can react with the paper do not attach the printout onto a mounting sheet with glue Replacing the Recording Pa...

Страница 58: ...Crapo Knudson Knudson 76 Polgar Composite Children Quanjer Tammeling Austria Indian Knudson Knudson 76 Polgar StandardsCompliance ATS OSHA NIOSH Technical Data Technical data subject to change without...

Страница 59: ...one Number Accessories PartNo Calibration pump 2 litres 2 100027 Pneumotacho sensor SP 250 2 200TBA Pack of 10 disposable sensors for SP 150 250 2 100077 Nose Clip 2 100084 Accessories Ordering The SC...

Страница 60: ...orous effort right from the start of the manoeuvre and continuing until absolutely no more air can be exhaled no leaning forward during the test Spirometry Tips How To Do It and Common Pitfalls and Pr...

Страница 61: ...irometer temperature to one degree Celsius Use of nose clip is encouraged Sitting or standing Reproducibility the highest and second highest FVC should agree to within 0 2L SpirometryTips How To Do It...

Страница 62: ...tongue obstruction glottic closure valsalva or early termination Reproducibility the highest and second highest FEV1 should agree to within 0 2L Spirometry Tips How To Do It and Common Pitfalls and Pr...

Страница 63: ...start has occurred should be rejected Vocalisation during the test will reduce flows and must be discouraged performing the manoeuvre with the neck extended often helps Spirometry Tips How To Do It an...

Страница 64: ...Test 6 FVC E I Test_ Screen Information_ 8 FVC_ 24 I Indian Equitations_ 34 K Knudson 76 Norm Values_ 39 Knudson Norm Values 38 L LLN value_ 27 Index A Accessories Ordering 49 American English 20 Aus...

Страница 65: ...Influences on Norm Values_ 11 S Safety standards_ 48 Select test 6 Slow Vital Capacity SVC Test 7 Standard English 20 Standards Compliance 48 Swedish Standards Berglund 32 Index M Measured Values 24...

Страница 66: ...T 2plus User Guide Spirometry Supplement Page 56 AT 2plus Spirometry Supplement Page 56 T Tabular Format 12 13 Technical Data 48 Temperature_ 22 T Tabular Format 12 13 Technical Data 48 Temperature_ 2...