Part Number: 000014110 Rev 01 1/19 19
3. To allow access for LuminIce® tubing,
the plastic caps in the bulkhead wall
must be removed and discarded. The
cap located behind the evaporator
will fall into the water trough. Remove
water trough to retrieve, then discard
cap and reinstall the water trough.
4. Assemble bracket, hoses and wires to
LuminIce® module.
• Short hose will route to access hole
behind the evaporator. Attach 90 degree
elbow to one end and attach other end
to LuminIce®.
• Long hose will route to the access hole
above the float switches. Attach 90
degree elbow to one end and attach
other end to LuminIce®.
• Route low voltage wiring (black and
yellow wires) to the LuminIce® module
and snap wire harness connectors
together.
• Attach both hoses to the bulkhead by
pressing in place.
• Secure excess wire to LuminIce® tubing.
5. Mount LuminIce® to ice machine with
2 screws.
6. Mount power supply on the left side
with two screws.
NOTE: Clearance holes for mounting the
LuminIce® are factory installed. Depending
on model, the power supply may mount
vertically or horizontally.