6-5
Problem
Probable Causes
Corrective Action
Controller
displays
TOPOFF OIL
EMPTY /
CONFIRM
Top off system out of oil.
Fill top off system with oil and press the
S
(CONFIRM) button.
6.2.6 Error Log Codes (For 3000 Controller Only)
Code ERROR
MESSAGE
EXPLANATION
E03
ERROR TEMP PROBE FAILURE
TEMP Probe reading out of range
E04
HI 2 BAD
High limit reading is out of range.
E05
HOT HI 1
High limit temperature is past more than 410
°
F
(210
°
C), or in CE countries, 395
°
F (202
°
C)
E06
HEATING FAILURE
A component has failed in the high limit circuit
such as controller, interface board, contactor or
open-high limit.
E07
ERROR MIB SOFTWARE
Internal MIB software error
E08
ERROR ATO BOARD
ATO board connection lost; ATO board failure
E15
ERROR MIB BOARD
Cooking controller detects MIB connections lost;
Check software version on each controller. If
versions are missing, check CAN connections
between each controller; MIB board failure
E17
ERROR ATO PROBE
ATO RTD reading out of range
E20
INVALID CODE LOCATION
SD card removed during update
E21
CHANGE FILTER PAPER
25 hour timer has expired. Change filter paper
and follow prompts.
E22
OIL IN PAN ERROR
Oil may be present in the filter pan.
E25
RECOVERY FAULT
Recovery time exceeded maximum time limit.
Recovery time should not exceed 1:40 for
electric.
E27
LOW TEMP ALARM
Oil temperature has dropped 30°F (17°C) lower
than setpoint in idle mode or 45°F (25°C) in cook
mode. (This message may appear if a product is
dropped and the start cook button is not pressed
immediately or if too large of cook loads are
dropped.)
6.2.7 HIGH-LIMIT TEST MODE
The high-limit test mode is used to test the high limit circuit. The high-limit test will destroy the oil.
It should only be performed with old oil. Shut the fryer off and call for service immediately if the
temperature reaches 460°F (238°C) without the high-limit tripping and the computer displays
high
LIMIT FAILURE
alternating with
DISCONNECT POWER
with an alert tone during testing.
The test is cancelled at any time by turning the fryer off. When the fryer is turned back on, it returns
to the operating mode and displays the product.
1. Press and hold the check (
9
)
button until
MAIN MENU
is displayed followed by
PRODUCT
SETUP
.
Содержание Frymaster FPEL114C