![Welbilt Frymaster FPEL114C Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/welbilt/frymaster-fpel114c/frymaster-fpel114c_installation-operation-and-maintenance-manual_953798011.webp)
2-3
2.1.3 Australian Requirements
To be installed in accordance with AS 5601, local authority, gas, electricity, and any other relevant
statutory regulations.
2.2 Power
Requirements
Three (3) Phase Requirements
MODEL VOLTAGE
WIRE
SERVICE
MINIMUM WIRE
SIZE
AWG (mm)
AMPS
(per leg)
FPEL14 208 3
6
(4.11)
39
FPEL14 240 3
6
(4.11)
34
FPEL14 480 3
8
(2.59)
17
FPEL14 220/380 4 6
(4.11)
21
FPEL14 240/415 4 6
(4.11)
20
FPEL14 230/400 4 6
(4.11)
21
FPEL17 208 3
6
(4.11)
48
FPEL17 240 3
6
(4.11)
41
FPEL17 480 3
6
(4.11)
21
FPEL17 220/380 4 6
(4.11)
26
FPEL17 240/415 4 6
(4.11)
24
FPEL17 230/400 4 6
(4.11)
25
Single Phase Requirements
MODEL VOLTAGE
WIRE
SERVICE
MINIMUM WIRE
SIZE
AWG (mm)
AMPS
(per leg)
FPEL14
208 2 3
(5.83)
68
FPEL14
240 2 4
(5.19)
59
FPEL14
480 2 8
(3.26)
30
NOTICE
If this appliance is permanently connected to fixed wiring, it must be connected by
means of copper wires having a temperature rating of not less than 167°F (75°C).
DANGER
This appliance must be connected to a power supply having the same voltage and
phase as specified on the rating plate located on the inside of the appliance door.
DANGER
All wiring connections for this appliance must be made in accordance with the
wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s)
affixed to the inside of the appliance door when installing or servicing this
equipment.
Содержание Frymaster FPEL114C
Страница 39: ...THIS PAGE INTENTIONALLY LEFT BLANK...