Part Number: 9295093  07/20 11

Section 2 

Installation

Model

Amp

H.P.

Voltage, Cycle, 

Phase

NEMA 

Plug

D4472NP-12

6

.35

115, 60, 1

5-15P

D4472NP-18

D4472NP-18M

D4472NP-24M

D4472NP-30M

Refrigerated Front Breathers With Doors & 4” S/S Backsplash

ST4427NP-6

4

.3

115, 60, 1

5-15P

ST4427NP-8

ST4448NP-6

4

.3

115, 60, 1

5-15P

ST4448NP-8

ST4460NP-8

6

.35

115, 60, 1

5-15P

ST4460NP-12

ST4460NP-12M

ST4460NP-18M

ST4464NP-8

6

.35

115, 60, 1

5-15P

ST4464NP-12

ST4464NP-12M

ST4464NP-18M

ST4472NP-12

6

.35

115, 60, 1

5-15P

ST4472NP-18M

ST4472NP-24M

Refrigerated Front Breathers With Drawers & 4” S/S Backsplash

STD4427NP-6

4

.3

115, 60, 1

5-15P

STD4427NP-8

STD4448NP-6

4

.3

115, 60, 1

5-15P

STD4448NP-8

STD4460NP-8

6

.35

115, 60, 1

5-15P

STD4460NP-12M

STD4460NP-18M

STD4464NP-8

6

.35

115, 60, 1

5-15P

STD4464NP-12

STD4464NP-12M

STD4464NP-18M

STD4472NP-12

6

.35

115, 60, 1

5-15P

STD4472NP-18M

STD4472NP-24M

Refrigerated Front Breathers w/ Doors & Raised Rail Prep Table

4448RP

4.0

.3

115, 60, 1

5-15P

4472RP

6.0

.35

115, 60, 1

5-15P

4496RP

6.0

.35

115, 60, 1

5-15P

Refrigerated Front Breathers w/ Drawers & Raised Rail Prep Table

D4448RP

4.0

.3

115, 60, 1

5-15P

D4472RP

6.0

.35

115, 60, 1

5-15P

D4496RP

6.0

.35

115, 60, 1

5-15P

Drain Connections

n

Warning

Moisture collecting from improper drainage can create a 

slippery surface on the floor and a hazard to employees. 

It is the owner’s responsibility to provide a container or 

outlet for drainage.

Self-contained models are standard with a condensate 

evaporator. If, for some reason, a cabinet does not have a 

condensate evaporator, or the evaporator fails, the cabinets 

drain must have an outlet to an appropriate drainage area or 

container.

Содержание Delfield 4400 Series

Страница 1: ...is equipment Fresh Solutions Fit For You Part Number 9295093 07 20 Compact Refrigerators 4400 Series Specifications Installation Operation Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest information ...

Страница 2: ... cleaning solutions for cleaning nWarning This product contains chemicals known to the State of California to cause cancer and or birth defects or other reproductive harm Operation installation and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers crystalline silica and or carbon monoxide Inhalation of airborne particles of glasswool or ceramic fibers ...

Страница 3: ... Leg Caster Installation 13 Changing Pan Height 13 Shelf Installation Instructions 13 Optional Overshelf Installation Instructions 14 Standard Cutting Board Bracket Mounting 15 Standard Bracket Adjustment 15 Heavy Duty Cutting Board Bracket Mounting 16 Section 3 Operation Power To Cool 19 Temperature Control 19 Efficient Operation 19 Defrost 19 Evaporator Fan Operation 19 Section 4 Maintenance Int...

Страница 4: ...th Doors 4427NP 6 One Door Salad Top 4427NP 8 4427NP 9M One Door Mega Top 4427NP 12M 4432NP 12M 4448NP 6 Two Door Salad Top 4448NP 8 4448NP 12 4448NP 6M Two Door Mega Top 4448NP 12M 4448NP 18M 4460NP 8 Two Door Salad Top 4460NP 12 4460NP 12M Two Door Mega Top 4460NP 18M 4460NP 24M 4464NP 8 Two Door Salad Top 4464NP 12 4464NP 12M Two Door Mega Top 4464NP 16 Two Door Salad Top 4464NP 18M Two Door Me...

Страница 5: ...efrigerated Front Breathers w Drawers 4 S S Backsplash STD4427NP 8 Two Drawer Salad Top STD4448NP 6 Four Drawer Salad Top STD4448NP 8 STD4460NP 8 STD4460NP 12 STD4448NP 6M Four Drawer Mega Top STD4448NP 12M STD4460NP 12M STD4460NP 18M STD4464NP 8 Four Drawer Salad Top STD4464NP 12 STD4464NP 12M Four Drawer Mega Top STD4464NP 18M STD4472NP 12 Six Drawer Salad Top STD4472NP 18M Six Drawer Mega Top S...

Страница 6: ...ont to back nWarning This equipment is intended for indoor use only Do not install or operate this equipment in outdoor areas The location selected for the equipment must meet the following criteria If any of these criteria are not met select another location Units are intended for indoor use only The location MUST be level stable and capable of supporting the weight of the equipment The location ...

Страница 7: ... D4464NP 12M D4464NP 16 D4464NP 18M D4464NP 24M D4472NP 12 545lbs 247kg D4472NP 18 D4472NP 18M D4472NP 24M D4472NP 30M Model Ship Weight Refrigerated Front Breathers With Doors 4 S S Backsplash ST4427NP 6 240lbs 109kg ST4427NP 8 ST4448NP 6 316lbs 143kg ST4448NP 8 ST4460NP 8 411lbs 186kg ST4460NP 12 ST4460NP 12M ST4460NP 18M ST4464NP 8 421lbs 191kg ST4464NP 12 ST4464NP 12M ST4464NP 18M ST4472NP 12 ...

Страница 8: ...rated Front Breathers With Drawers D4427NP 6 27 69cm 31 50 80cm 36 00 91cm D4427NP 8 D4427NP 9M D4427NP 12M D4432NP 12M 32 81cm 31 50 80cm 36 00 91cm D4448NP 6 48 122cm 31 50 80cm 36 00 91cm D4448NP 8 D4448NP 12 D4448N 18M Model Length Depth Work Height D4460N 8 60 152cm 31 50 80cm 36 00 91cm D4460NP 12 D4460NP 12M D4460NP 18M D4460NP 24M D4464NP 8 64 163cm 31 50 80cm 36 00 91cm D4464NP 12 D4464NP...

Страница 9: ...L D4460NP 12 12 D4460NP 12M 12 D4460NP 18M 18 D4460NP 24M 24 D4464NP 8 8 NA 21 60ft3 612L D4464NP 12 12 D4464NP 12M 12 D4464NP 16 16 D4464NP 18M 18 D4464NP 24M 24 Model 1 6 Pan Capacity Shelf Area Base Volume D4472NP 12 12 NA 24 80ft3 702L D4472NP 18 18 D4472NP 18M 18 D4472NP 24M 24 D4472NP 30M 30 Refrigerated Front Breathers With Doors 4 S S Backsplash ST4427NP 6 6 3 17ft2 2945cm2 8 20ft3 232L ST...

Страница 10: ... of GFCI GFI circuit protection to energize our equipment If code requires the use of a GFCI GFI then you must follow the local code The circuit must be dedicated sized properly and there must be a panel GFCI GFI breaker We do not recommend the use of GFCI GFI outlets to energize our equipment as they are known for more intermittent nuisance trips than panel breakers RATED AMPERAGES HORSEPOWER VOL...

Страница 11: ...STD4460NP 18M STD4464NP 8 6 35 115 60 1 5 15P STD4464NP 12 STD4464NP 12M STD4464NP 18M STD4472NP 12 6 35 115 60 1 5 15P STD4472NP 18M STD4472NP 24M Refrigerated Front Breathers w Doors Raised Rail Prep Table 4448RP 4 0 3 115 60 1 5 15P 4472RP 6 0 35 115 60 1 5 15P 4496RP 6 0 35 115 60 1 5 15P Refrigerated Front Breathers w Drawers Raised Rail Prep Table D4448RP 4 0 3 115 60 1 5 15P D4472RP 6 0 35 ...

Страница 12: ...M D4464NP 24M D4472NP 12 2973 2042 72g D4472NP 18 D4472NP 18M D4472NP 24M D4472NP 30M Model BTU Hour Capacity Heat of Rejection R290 Charge Refrigerated Front Breathers With Doors 4 S S Backsplash ST4427NP 6 2038 716 60g ST4427NP 8 ST4448NP 6 2038 1299 60g ST4448NP 8 ST4460NP 8 2973 1645 72g ST4460NP 12 ST4460NP 12M ST4460NP 18M ST4464NP 8 2973 1664 72g ST4464NP 12 ST4464NP 12M ST4464NP 18M ST4472...

Страница 13: ...out proper blocking Do not lift the unit more than necessary to remove the leg caster Lifting the unit too far can make the unit unstable Caution All single section units require that the swivel casters be mounted on the front and rigid casters be mounted on the rear Changing Pan Height If additional pan temperature cooling ability is desired especially in higher ambient temperature conditions and...

Страница 14: ...p side of the cabinet total six screws 2 Set the overshelf in place on the top of the cabinet 3 Line up the overshelf holes with the unit holes 4 Secure with three screws per side of the cabinet total six screws If the overshelf was not ordered with the unit 1 Set the overshelf in place on the top of the cabinet 2 Secure with three screws per side of the cabinet total six screws ...

Страница 15: ...24092 2 Fender Washer 9324043 Parts Included For 48 Units Qty Description Part No 1 Left Bracket Varies 1 Center Bracket Varies 1 Right Bracket Varies 1 Silicone 9291311 3 Screw pan head 9321519 3 Screw flat head 9324092 3 Fender Washer 9324043 Parts Included For 60 64 72 Units Qty Description Part No 1 Left Bracket Varies 2 Center Bracket Varies 1 Right Bracket Varies 1 Silicone 9291311 4 Screw p...

Страница 16: ...324043 and one pan head screw 9321519 Some adjustment to align the brackets may be necessary once the cutting board is installed Do not over tighten the screws Face 3 Install the cutting board onto the brackets Make final bracket adjustments so the cutting board sits flush in the brackets Tighten screws 4 Silicone 9291311 each bracket anyplace it touches the top or face of the unit This prevents f...

Страница 17: ...Part Number 9295093 07 20 17 Section 2 Installation THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 18: ... nWarning The operator of this equipment is solely responsible for ensuring safe holding temperature levels for all food items Failure to do so could result in unsafe food products for customers nWarning Overloading shelves can damage equipment or cause bodily injury nWarning Damp or wet hands may stick to cold surfaces nWarning Do not block the supply and return air grills or the air space around...

Страница 19: ...tion Cabinets with pans should be operated with pans in place Operating the cabinet without all pans in place may damage the cabinet Continuous opening and closing of the door will hamper the cabinet s ability to maintain optimum refrigeration temperature Top section is not intended for overnight storage Product should be removed from pans Pans can remain in cabinet while empty Defrost The electro...

Страница 20: ...ainted surfaces Caution Maintenance and servicing work other than cleaning as described in this manual must be done by an authorized service personnel Caution Over shelves and other items mounted to the top of the counters should never be installed in the field due to the potential damage to the refrigeration system Responsibility You are responsible for maintaining the equipment in accordance wit...

Страница 21: ...ube is in the condensate evaporator The leveling of the unit is important as the units are designed to drain properly when level Be sure all drain lines are free of obstructions Drawer Assembly Cleaning The drawer assembly is designed to be cleaned easily Both drawer and tracks are removable without tools The drawer tracks are dishwasher safe or can be cleaned in a sink with detergents and a soft ...

Страница 22: ...ain a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with a dirty or clogged condenser coil can result in compressor failure Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor and cost to replace the compressor Doors Hinges Over time and with heavy use doors the hinges may become loose I...

Страница 23: ...Part Number 9295093 07 20 23 Section 4 Maintenance THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 24: ...DELFIELD 980 SOUTH ISABELLA ROAD MOUNT PLEASANT MI 48858 800 733 8821 WWW DELFIELD COM 2019 Welbilt Inc except where explicitly stated otherwise All rights reserved Part Number 9295093 07 20 ...

Отзывы: