Part Number: 9295093 07/20
Installation
Section 2
Electrical Service
DANGER
Check all wiring connections, including factory terminals,
before operation. Connections can become loose during
shipment and installation.
n
Warning
This appliance must be grounded and all field wiring must
conform to all applicable local and national codes. Refer
to rating plate for proper voltage. It is the responsibility of
the end user to provide the disconnect means to satisfy
the authority having jurisdiction.
• The Danfoss control can be used to power down and shut
off the unit.
• All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
• The equipment must be grounded.
• A separate fuse/circuit breaker must be provided for each
unit.
• The maximum allowable voltage variation is ±10% of the
rated voltage at equipment start-up (when the electrical
load is highest).
• Check all green ground screws, cables and wire
connections to verify they are tight before start-up.
GROUND FAULT CIRCUIT INTERRUPTER
Ground Fault Circuit Interrupter (GFCI/GFI) protection is a
system that shuts down the electric circuit (opens it) when it
senses an unexpected loss of power, presumably to ground.
Welbilt does not recommend the use of GFCI/GFI circuit
protection to energize our equipment. If code requires the
use of a GFCI/GFI then you must follow the local code. The
circuit must be dedicated, sized properly and there must
be a panel GFCI/GFI breaker. We do not recommend the
use of GFCI/GFI outlets to energize our equipment as they
are known for more intermittent nuisance trips than panel
breakers.
RATED AMPERAGES, HORSEPOWER, VOLTAGE & POWER
CORD CHART
Maximum 6ft (1.8m) cord with three-pronged plug. Plug
into a three-pronged wall outlet for proper grounding of the
cabinet to begin operation. Do not use an adapter to connect
to a two-pronged outlet.
Model
Amp
H.P.
Voltage, Cycle,
Phase
NEMA
Plug
Refrigerated Front Breathers With Doors
4427NP-6
4
.3
115, 60, 1
5-15P
4427NP-8
4427NP-9M
4427NP-12M
4432NP-12M
4
.3
115, 60, 1
5-15P
4448NP-6
4
.3
115, 60, 1
5-15P
4448NP-8
4448NP-12
4448NP-18M
4460NP-8
6
.35
115, 60, 1
5-15P
4460NP-12
4460NP-12M
4460NP-18M
4460NP-24M
4464NP-8
6
.35
115, 60, 1
5-15P
4464NP-12
4464NP-12M
4464NP-16
4464NP-18M
4464NP-24M
4472NP-12
6
.35
115, 60, 1
5-15P
4472NP-18
4472NP-18M
4472NP-24M
4472NP-30M
Refrigerated Front Breathers With Drawers
D4427NP-6
4
.3
115, 60, 1
5-15P
D4427NP-8
D4427NP-9M
D4427NP-12M
D4432NP-12M
4
.3
115, 60, 1
5-15P
D4448NP-6
4
.3
115, 60, 1
5-15P
D4448NP-8
D4448NP-12
D4448NP-18M
D4460NP-8
6
.35
115, 60, 1
5-15P
D4460NP-12
D4460NP-12M
D4460NP-18M
D4460NP-24M
D4464NP-8
6
.35
115, 60, 1
5-15P
D4464NP-12
D4464NP-12M
D4464NP-16
D4464NP-18M
D4464NP-24M