25
Original instructions.
OPERATION
Installed
correctly.
Portafilter is not
fully inserted.
Group gasket is worn
out and needs to be
replaced.
Align the portafilter's two flanges with the
two slots in the group housing.
Insert the portafilter and rotate it
counterclockwise until the handle is
approximately perpendicular to the face of
the coffee machine.
· Inserting the portafilter in the group
· Espresso brewing
1. Unlock and remove the portafilter from the group head.
2.
Fill the filter basket with espresso-grind coffee (approx. 7g for single or 14g for a double espresso).
3. Compact the coffee.
4. Insert the filled portafilter into the group head and lock it into the correct position.
5. Place the cup(s) under the portafilter.
6. Select the desired option from the drink button to begin brewing.
WARNING!
Never try to open the portafilter while the
machine is in operation! The pressurised hot
water could cause scalding or serious injury.
After dispensing has finished, wait at least 3
seconds before removing the portafilter.
Pro Tip:
When not in use store the portafilter
inserted in the group to keep it warm.
This is important to maintain optimal
brewing temperature while the
espresso is dispensing.