background image

19.

LUBRICATION PROCEDURE 

Lubricate the following parts every three months to insure 

smooth operation and reduce wear. 

 

TRUNNION HOUSING, 
WORM SCREW AND 
TILT GEAR

 

These parts are accessed 

through the top cover of the 
console.  

Apply grease to gear teeth. 
Check for excessive play and 
adjust with adjusting screw 
located on top of cross bar.

 

 

KETTLE TRUNNIONS 

 

On the left hand side of the 

kettle there are two grease 
nipples on the top back 
portion of the trunnion 
housing. On the right hand 
side of the kettle you must 
remove the console cover to 
access the two grease 
nipples.

Adjusting

Screw

Worm
Screw and
Tilt
Gear

Cross

Bar

Trunnion Housing

Grease Nipple

HINGE ADJUSTMENT 
INSTRUCTIONS

1.

Insert 3/8" Allen wrench. 

2.

Turn clockwise to relieve tension on spring. 

3.

While tension is released remove one of the two 
slotted screws. 

4.

To prevent Allen wrench from springing back abruptly 
while the second slotted screw is removed, insert a pin 
(approximately 1/8") in the hole where the first slotted 
screw was removed from. 

5.

Remove second slotted screw. 

6.

While holding Allen wrench remove pin. 

7.

Turn Allen wrench clockwise to tighten or counter-
clockwise to loosen tension to produce desired effect. 

8.

Re-insert pin in one of the two holes. 

9.

Tighten one slotted screw in the other hole (it may be 
necessary to turn Allen wrench slightly to align holes). 

10.

Remove pin and repeat step number 9 for other 
slotted screw.

3/8" Allen wrench

1. If required remove board from holding bracket for better 

access. 

2. Turn unit on and set to 10 (maximum). 

3. Push and hold the SWITCH button for approximately 5 

seconds until the CPU starts to flash 1 flash/second. You 
are now in TEST #1.  Output to 12v relay is disabled. With 
kettle upright the DIAGNOSTIC LED should be green, with 
kettle tilted it should be red. 

4. Push SWITCH button. The CPU starts to flash 2 

flash/second. You are now in TEST #2. Check the 
DIAGNOSTIC LED for indication of the temperature probe 
status. 

5. Push SWITCH button. The CPU starts to flash 3 

flash/second. You are now in TEST #3. The HEATER 
OUTPUT LED should light for 20 seconds and power to 
the relay should energize the 12v relay for the heat source. 

After 20 seconds test mode is exited and unit reverts to 
normal operation.

THIS C

ONTROL BO

X MUST BE

C

ALIBR

ATED WHEN 

REPL

A

CED

(see back f

or t

est and

calibration instruc

tions)

SSK Solid State Control

 (part number KE00458-1)

DIA

G

NOSTIC LED

 

SWIT

CH

 

CPU

SWITCH

 -  Push for 5 seconds to enter TEST #1

 

Press again for TEST #2 and again for TEST #3

CPU

 - 

Rapid flashing during normal operation

 

TEST #1 = 1 flash/sec Water level test

 

TEST #2 = 2 flash/sec Thermistor test

 

TEST #3 = 3 flash/sec Heater Ouput test

 

TEST #1

  GREEN 

Probe senses water

 

RED 

No water sensed

TEST #2

  GREEN 

Thermistor is sensed

 

ORANGE  Thermistor is shorted

 

RED 

Thermistor is open circuit

 

POTENTIOMETER

LOW WATER

HEATER OUTPUT

TEST #3  GREEN voltage output 

to relay for 20 seconds.

Normal operation LED matches 

Front heater (greeen) LED

SSK SOLID STATE CONTROL 
TEST INSTRUCTIONS

Содержание Cleveland MKEL-100-T

Страница 1: ...odel Serial Installation Operation Maintenance Parts Service This manual is updated as new information and models are released Visit our website for the latest manual Electric Vertical Mixer Kettles P...

Страница 2: ...onformer aux mesures de s curit normalis es de l industrie y compris mais sans s y limiter les r glementations de l OSHA les proc dures de d branchement verrouillage tiquetage relatives tous les servi...

Страница 3: ...es proximit de cet appareil ou de tout autre appareil Ne pas pulv riser des a rosols dans le voisinage de cet appareil alors qu il est en fonctionnement Cet appareil ne doit pas tre utilis par des per...

Страница 4: ...lief discharge Restez l cart de la soupape de suret Permanezca alejado de la descarga de presi n Do not lean on or place objects on lip Ne vous penchez pas sur oune placez pas des objets sur la l vre...

Страница 5: ...ing out the claim forms later 2 As soon as damage is discovered or suspected notify the carrier that delivered the shipment 3 Arrange for the carrier s representative to examine the damage 4 Fill out...

Страница 6: ...MOVING UNIT 1 While still on skid move unit as close to final installation position as possible 2 Prepare unit for lifting as shown in diagram 3 Lift gently with a forklift or jacks and remove skid 4...

Страница 7: ...Switch to mix Turn speed control to zero to reset micro switch then set speed control to number four Check that unit does not begin to mix until bridge has lowered part way into the kettle Check that...

Страница 8: ...tor motors 16 MAIN AGITATOR ARM Provides most of the product movement 17 SECONDARY AGITATOR ARM Provides reverse agitation and product lift in kettle 18 SECONDARY SPEED CONTROL KNOB Controls speed of...

Страница 9: ...ty As a safety precaution the MIXER SPEED CONTROL must first be turned to zero before unit will start to mix Always remember like a cooking pot the kettles become very hot when cooking Avoid contact w...

Страница 10: ...ixing 1 Turn MIX LIFT SWITCH to mix icon B 2 Turn MIXER SPEED CONTROL SWITCH to 0 and slowly adjust to desired speed 3 Adjust SECONDARY SPEED CONTROL KNOB to desired speed Tilting Kettle 1 Raise MIXER...

Страница 11: ...ater and mild detergent solution c Remove food deposits using a nylon brush d Rinse with fresh water e Leave valve open when unit is not in use 10 If the unit is equipped with an Air Valve clean as fo...

Страница 12: ...ing models only SIX MONTH SERVICE INSPECTION 1 Perform daily startup inspection 2 Gaskets are in good condition 3 Tilt hand wheel is tight 4 Grease bearings on both trunnions 5 Check for play in gears...

Страница 13: ...t of 16 VAC transformer Yes Go to step 9 No Replace defective 240 16 VAC transformer Possible Causes 1 No incoming power 2 Kettle is tilted 3 Low water condition 4 Defective ON OFF switch 5 Defective...

Страница 14: ...mum operating pressure of 30 35 psi in an empty kettle Yes Kettle is operating correctly No Spray contact cleaner on control terminals and edge connector Try box again If problem still exists replace...

Страница 15: ...ontrol box No Kettle is operating correctly B MECHANICAL CHECKS 1 Inspect controls replace damaged seals switches LED s etc 2 Remove the console cover and check that the seal is not cracked or split R...

Страница 16: ...n how the installer wired the kettle you may have to remove the supply wire and reconnect 4 Physically push in on contacts of each contactor to check for free movement Replace contactor s if required...

Страница 17: ...of the above criteria is not met replace valve The above illustrations show the variations of factory installed Safety Valves Any modifications are unacceptable 4 maximum length Correct Installation I...

Страница 18: ...urrounds tube and thermistor 10 Replace covers reconnect power and test operation REPAIRING LEAKS IN STEAM JACKETED KETTLE FITTINGS If unit will not hold a vacuum the most likely cause is a leak at on...

Страница 19: ...3 5 6 7 8 9 1 4 10 OFF 50 0 100 150 200 250 300 350 400 40 50 60 0 10 20 30 psi kPa V E N T A I R 50 0 100 150 200 250 300 350 400 40 50 60 0 10 20 30 psi kPa V E N T A I R 50 0 100 150 200 250 300 35...

Страница 20: ...9 for other slotted screw 3 8 Allen wrench 1 If required remove board from holding bracket for better access 2 Turn unit on and set to 10 maximum 3 Push and hold the SWITCH button for approximately 5...

Страница 21: ...ace low water probe 2 Remove pressure relief valve and replace with street elbow 3 Using a small funnel one made of paper works great slowly pour water into the kettle 5 Allow kettle to drain again 6...

Страница 22: ...y tightening nut G 8 Scraper arm should now go from no rotation to fast rotation by turning speed control knob NOTE Mixer may run rough and noisy for one or two hours if air has become trapped in the...

Страница 23: ...WIRING DIAGRAM SINGLE KETTLES consult factory for other wiring configurations...

Страница 24: ...WIRING DIAGRAM TWIN KETTLES consult factory for other wiring configurations...

Страница 25: ...r bridge Raise bridge B Mix Lift 3 Way Solenoid Valve Flow Control Valve Flow Control Valve Hydraulic Cylinder single acting Filter Relief Valve set at 1000 psi Check Valve Pressure Gauge C Blocking V...

Страница 26: ...03844 ITEM PART DESCRIPTION QTY NO NO A KE50343 12 Fuse Mounting 1 Plate B KE51139 1 Fuse Holder 3 C KE52936 21 Fuse 20A 600V 3 KLDR20 Slow Blow D FA15018 3 8 32x1 4 Phil 4 Pan Head Screw A C B D See...

Страница 27: ...gitator 40 gal includes 44 1 KE00936 Secondary Agitator 60 gal includes 44 1 KE00937 Secondary Agitator 80 gal includes 44 1 KE00938 Secondary Agitator 100 gal includes 44 1 KE00939 Secondary Agitator...

Страница 28: ...18 1 FI05072 BULKHEAD 90 UNION ELBOW 19 1 KE52222 1 METAL GEAR 3 4 BORE 20 1 KE52224 PLASTIC GEAR COUPLING 21 1 KE00698 PUMP MTG PEDESTAL 22 1 KE52222 2 METAL GEAR 1 1 8 BORE 23 4 FA11509 2 HEX HEAD...

Страница 29: ...E RELIEF VALVE 1 24 FI05054 MALE BRANCH TEE FITTING 1 25 FI05069 STREET TEE 1 26 FI05034 STRAIGHT THREAD ADAPTER 2 27 FI05030 1 ELBOW 3 8 1 1 4 90 DEG 1 50 0 100 150 200 250 300 350 400 40 50 60 0 10...

Страница 30: ...CONTACT CONTACT PART NUMBER KE603208 1 KE603208 2 KE603208 3 KE603208 4 KE603208 5 KE603208 6 KE603208 7 KE603208 8 KE603208 9 OF 2 3 2 3 3 POSTITIONS maintained maintained spring spring spring flush...

Страница 31: ...838 2 KE53838 3 KE52055 25 24 KE52055 KE53838 2 THERMAL OVERLOAD HEATER TRANSFORMER TRANSFORMER THERMAL OVERLOAD HEATER THERMAL OVERLOAD HEATER TRANSFORMER 250VA 3 1 2 1 1 3 DESCRIPTION 30 KE00888R CO...

Страница 32: ...1 Nut 3 9 KE52280 Weather Strip 76 long 1 10 KE01820 Ambient Heater Assembly 1 11 SK50370 1 Terminal Block 2 Section 1 SK50370 2 Terminal Block 45 2 SK50370 3 Terminal Block 90 2 12 KE54402 Mounting B...

Страница 33: ...gallon 380 415V 6 KE53838 12 40 100 gallon 440 480V 6 12 TERMINAL BLOCKS KE50377 40 100 gallon 200 240V high wattage 6 elements 6 SK50055 1 ALL OTHERS 6 13 TERMINAL BLOCK ENDS KE50376 40 100 gallon 20...

Страница 34: ...03209 3 Switch Assembly On Off On Maintained 6 KE003209 4 Switch Assembly On Off Maintained single kettle 1 twin kettle 2 7 KE003209 5 Switch Assembly On Off ON Maintained 1 8 KE003209 11 Switch Assem...

Страница 35: ...ree 1 11 KE51861 Gallon Meter 1 KE51860 Litre Meter 12 FI00062 Elbow 90 Degree 1 13 KE52173 1 2 1 D Hot Water Wash up Hose 1 14 FI05220 3 Hose Clamp 2 15 FI00179 Tee 1 16 FI05074 Nipple 2 KE600362 Nip...

Страница 36: ...24 100 150 GAL 2 21 KE00699 1 TRUNNION HSG WLD T MACH 1 KE01182 1 TRUNNION HSNG ASS Y 2 1 22 KE51629 1 TRUNNION SLEEVE 2 PIPE 1 KE51629 3 TRUNNION SLEEVE 3 TUBE 1 23 KE00151 SEGMENT GEAR SMALL 1 5 1 K...

Страница 37: ...36 SEE ABOVE COMPONENT PLATE ASSEMBLY POWER TILT KETTLES KE02185 C...

Страница 38: ...MODIFIED CORRECTIONAL PACKAGE 1 6 FA05002 24 O RING TD 1 5 1 FA05002 38 O RING TD 3 1 7 SE50005 VALVE BODY TD 1 5 1 KE50973 VALVE BODY TD 3 1 1 2 3 4 5 6 7 8 TANGENT DRAW OFF VALVES ITEM NO PART NO D...

Страница 39: ...PTION QTY 1 7 KE52286 Butterfly Valve includes housing 1 1 FA11224 Bolt 5 16 18x1 S S 6 2 FA21024 Nut 5 16 18 6 3 SE50433 1 Seat 1 4 SE50434 1 Stem 1 5 SE50435 1 Locking Spider 1 6 SE50436 Handle Asse...

Страница 40: ...OID ASSEMBLY FOR FPVA 3 KE02340 C SPARE PARTS LIST PART NO DESCRIPTION QTY KE51834 SCRAPER BLADES 5 KE00860 SPEED CONTROL CABLE ASSEMBLY 1 KE52936 6 FUSE 3 AMP 2 KE50753 10 RELAY 2 5 KE52936 16 FUSE 2...

Страница 41: ...40...

Страница 42: ...tchencare com To learn how Welbilt Foodservice and its leading brands can equip you visit our global web site at www welbilt com then discover the regional or local resources available to you Every ne...

Отзывы: