![WEISS TS004E Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/weiss/ts004e/ts004e_user-manual_953406009.webp)
Electronic Control Card TS004E
Technical data
4
Technical data
4.1
Technical data "Control Cad"
Characteristic
Unit
Value
Operating voltage
V
24 (± 10%)
Current input
mA
Typ. 40 (without 24 V holding brake)
Input power holding brake
A
DC
1.0 ... 2.0 (depends on type)
Digital inputs
V
Level LOW: 0 ... 5
HIGH: 15 ... 30
Input current: 6 mA
Digital outputs
mA
Output current: 100
(outputs: 4, 6, 7, 8, 9, 10)
Output current: 2000
(outputs: C, D, E)
Electromagnetic compatibility
Harmonized standard as per European directive
2014/30/EU:
Harmonic current emissions
Immunity
Emissions
-
EN 61000-3
EN 61000-4
EN 55014-1
Dimensions
mm
Eurocard: 100 x 160
4.2
Technical data "Terminal PCB"
Termi-
nal
Function
Level
Remark
32-pin mul-
tipoint con-
nector
+
+24 V
-
Supply voltage
3/4/A/B
-
GND (OV)
-
Supply voltage
1/2/A/B
1
Direction of rotation
LOW
CW
HIGH
CCW
Input 24 V
26A
2
Enable
(RESET/STOP)
LOW:
-Disable
-Reset Alarm
HIGH:
Enable
Input 24 V
19A
3
Start edge
Rising edge
Input 24 V
18A
4
Automatic
-
Output 24 V/100 mA 16B
5
Additional stop
Log.
1
active
Input 24 V
18B
6
position overrun
-
Output 24 V/100 mA 10B
7
Motor overload
(movement timeout)
-
Output 24 V/100 mA 10A
User manual_082018_1.0_en
9 / 29