This user manual describes the product Electronic Control Card TS004E (also referred to as "product"

in this document).
This user manual is a part of the product.

You may only use the product if you have fully read and understood this user manual.

Verify that this user manual is always accessible for any type of work performed on or with the

product.

Pass this encoder as well as all other product-related documents on to all owners of the product.

If you feel that this user manual contains errors, inconsistencies, ambiguities or other issues, contact

the manufacturer prior to using the product.

There mounting instructions are protected by copyright and may only be used as provided for by the

corresponding copyright legislation. We reserve the right to modifications.
The manufacturer shall not be liable in any form whatsoever for direct or consequential damage

resulting from failure to observe this user manual or from failure to comply with directives, regulations

and standards and any other statutory requirements applicable at the installation site of the product.

1.2

Intended use

This product is a component for installation in control cabinets; it may only be used within the limits

specified in this user manual and in the applicable documents. The applicable documents are also part

of the product.
The machinery must not be put into service until the machinery into which the product has been

incorporated has been determined and declared in conformity with the provisions of Directive 2006/42/

EU and of the EMC Directive 2014/30/EU and with all other applicable directives and regulations.
In addition, perform a risk assessment in view of the planned application, according to an approved risk

assessment method, and implement the appropriate safety measures, based on the results of the risk

assessment. Take into account the consequences of installing or integrating the product into a system

or a plant.
WEISS devices comply with the applicable regulations of VDE. The VDE regulations must also be

observed for modification or disassembly of the device. This manual contains information on EMC-

compliant installation. The manufacturer of the machine or system is responsible for compliance with

all applicable EMC regulations and directives.

1.3

Predictable incorrect application

Any use of the product beyond the explicitly indicated intended use is an impermissible, incorrect

application of the product.
The product must never be used in the following cases, under the following conditions, and for the

following purposes:

Operation of the product in potentially explosive atmospheres/hazardous areas

4 / 29

User manual_082018_1.0_en

Содержание TS004E

Страница 1: ...ELECTRONIC CONTROL CARD TS004E USER MANUAL TD0080A EN00 0000 00 082018_1 0_EN ELECTRONIC CONTROL CARD TS004E USER MANUAL TD0080A EN00 0000 00 082018_1 0_EN...

Страница 2: ...l data 9 4 1 Technical data Control Cad 9 4 2 Technical data Terminal PCB 9 4 3 Climatic environmental conditions operation 10 4 4 Climatic environmental conditions transportation and storage 10 4 5 D...

Страница 3: ...l 10 21 8 3 7 Terminal C 21 8 3 8 Terminal D 21 8 3 9 Terminal E 21 9 Operation 22 9 1 Normal operation one direction of rotation 22 9 2 Forward reverse operation two directions of rotation 23 10 Erro...

Страница 4: ...in the limits specified in this user manual and in the applicable documents The applicable documents are also part of the product The machinery must not be put into service until the machinery into wh...

Страница 5: ...s Operating instructions and mounting instructions of all products belonging to the scope of delivery for example motor accessories attachment parts This includes among other things Delivery Type of m...

Страница 6: ...dous situation which if not avoided can result in death or serious injury or equipment damage CAUTION CAUTION indicates a hazardous situation which if not avoided can result in injury or equipment dam...

Страница 7: ...ation site of the product If the system integrator himself is not in the position to comply with any of these obligations the system integrator must impose compliance with these obligations on the ope...

Страница 8: ...gnal to the processing station The motor is stopped when a delay time has elapsed which is set via the switches at the counter display This way the drive moves to a start position for the next cycle T...

Страница 9: ...pean directive 2014 30 EU Harmonic current emissions Immunity Emissions EN 61000 3 EN 61000 4 EN 55014 1 Dimensions mm Eurocard 100 x 160 4 2 Technical data Terminal PCB Termi nal Function Level Remar...

Страница 10: ...tor contactor reverse 14A B F Sensor Log 1 active Input 24 V 15B G Release brake Log 1 active Input 24 V 15A H Start state controlled Log 1 active Input 24 V 17B T Temperature sensor Log 0 active Inpu...

Страница 11: ...Electronic Control Card TS004E Technical data 4 5 Dimensions Figure 1 Lengths in mm User manual_082018_1 0_en 11 29...

Страница 12: ...hotographs of the damage Report the damage to WEISS GmbH 5 2 Packaging and shipment The product is delivered in an accurately fitting plastic packaging 5 3 Unpacking the product NOTICE ELECTROSTATIC D...

Страница 13: ...ment damage The components of the product can be stored for a period of up to two years Conditions for the specified maximum storage duration Storage in original packaging Compliance with all specifie...

Страница 14: ...e card holder has screw terminals on the left and right hand sides for the connection of the 24 V cables and the signal cables Housings All housings have a terminal PCB already mounted Front panel mou...

Страница 15: ...r cable is switched by means of an electronic contactor solid state relay The contacts of the Emergency Stop contactors must be installed between the electronic contactor and the motor Refer to the in...

Страница 16: ...g or disconnecting the electrical connections of the product Failure to follow these instructions will result in death or serious injury 8 1 Controls and status indicators 1 Button START The LED light...

Страница 17: ...h cycle The basic increments for the stop delay are 20 40 or 80 ms This is set by means of a switch on the PCB The factor is set at the buttons of the counter indicator stop delay to a value between 0...

Страница 18: ...erating modes BRAKE release INCHING and AUTOMATIC The key can be removed in any of the positions BRAKE release If you release the brake you can manually rotate the rotary indexing table rotary indexin...

Страница 19: ...a complete cycle The start pulse must have a pulse width of at least 20 msec If the level remains HIGH this does not trigger a new start The jumper N 2H must be at the left position The terminal H ha...

Страница 20: ...at the right hand posi tion Terminal 3 has no effect 8 2 8 Terminal T Temperature monitoring The temperature switch normally closed contact of motors with temperature monitoring can be connected to th...

Страница 21: ...y indexing table rotary indexing ring is in a valid position The rotary indexing table rotary indexing ring is equipped with a position cam The inductive sensor detects this position cam and the signa...

Страница 22: ...Electronic Control Card TS004E Operation 9 Operation 9 1 Normal operation one direction of rotation 22 29 User manual_082018_1 0_en...

Страница 23: ...Electronic Control Card TS004E Operation 9 2 Forward reverse operation two directions of rotation User manual_082018_1 0_en 23 29...

Страница 24: ...ust the holding brake see mounting instructions TD0003A TD0070A TD0026A see chapter 1 4 Motor over load movement timeout LOW HIGH HIGH Position cam on output flange does not reach the inductive sensor...

Страница 25: ...ct in compliance with all applicable directives standards and safety regulations Environmental protection Dispose of lubricants greases residue of cleaning agents and other non recyclable materials ac...

Страница 26: ...28806 Alcal de Henares Madrid Phone 34 91 830 06 86 Fax 34 91 830 06 87 E mail info weiss gmbh es UNITED KINGDOM WEISS UK Ltd Meridian House Winsford Ind Estate Winsford Cheshire CW7 3RG Phone 44 1606...

Страница 27: ...12 3 Ordering spare parts WARNING UNSUITABLE SPARE PARTS AND ACCESSORIES Only use spare parts and accessories which are approved by the manufacturer Failure to follow these instructions can result in...

Страница 28: ...control card TS004E Control card with Czech label 1 EH0004K 0000 0002 00 Terminal PCB 1 EH0004L 0000 0000 00 Card holder 1 EG0004R 0000 0001 00 Housings Screw mounting 1 EG0004F 0000 0001 00 Housings...

Страница 29: ...WEISS GmbH Siemensstra e 17 74722 Buchen Telefon 06281 5208 0 Telefax 06281 5208 99 info weiss international com www weiss international com...

Отзывы: