OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER EQ1-MK2
TECHNICAL DATA
Daniel Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster
Page 24 of 26
)
+41 1 940 20 06
2
+41 1 940 22 14
8
http://www.weiss.c
*
Overall Gain CH2
Control Change
1011 cccc
01000111 ($47)
(cccc) Channel No.
0vvv vvvv
(vvvvvvv) New Value:
0 - 127
CH1 / 2 SELECT
Control Change
1011 cccc
01001000 ($48)
(cccc) Channel No.
0vvv vvvv
(vvvvvvv) New Value:
0, 1
EQ Bypass
Control Change
1011 cccc
01001001 ($49)
(cccc) Channel No.
0vvv vvvv
(vvvvvvv) New Value:
0, 1
Set Ganged Mode
Control Change
1011 cccc
01001010 ($4A)
(cccc) Channel No.
0vvv vvvv
(vvvvvvv) New Value:
0, 1
Toggle A <> B
Control Change
1011 cccc
01001011 ($4B)
(cccc) Channel No.
0vvv vvvv
(vvvvvvv) New Value:
0, 1
MSC Mode
Control Change
1011 cccc
01001100 ($4C)
(cccc) Channel No.
0vvv vvvv
(vvvvvvv) New Value:
Bit 0: on/off, 1=on
Bit 1: Input: 1=MSC, 0=L/R
Bit 2: EQ: 1=MSC, 0=L/R
Bit 3: Output: 1=MSC, 0=L/R
Bit 4: 1 = CH swap, 0= norm
System Reset
1111 1111
-
Recall Snapshot 0 to WS A
Dump Remote Control
All System-Exklusive commands consist of a header, a message type, possible data and the EOS (end of
system exclusive). Below is the format of the header:
Byte
Value
Description
Section
1
F0
Sysex
Header
2
00
Manufacturer's ID
3
30
Manufacturer's ID
4
5A
Manufacturer's ID
5
06
Model ID: 6 = Gambit EQ
6
0000nnnn
Device ID: -> Midi channel number
Following is a list of the supported MIDI system exclusive commands (without header):
Snapshot format for dump. A complete dump consists of 128 snapshots:
Byte
Value
Description
Section
1-6
...
...
Header
7
00000001
message = Snapshot dump
Message Type
8
0nnnnnnn
Package number ( 0..7F)
Data
9
0nnnnnnn
scale set number
10 - 265
0nnnnnnn
256 Bytes of Snapshot data
266
0ccccccc
Checksum without byte one (F0 Sysex Command)
Checksum
267
F7
EOS
EOS