the system will promot error when detecting the size or CAD
fauls.Please re edit.
E1O
E10 Vacuum pump
alarm
The plate is with the function of vacuum.The fun of vacuum
pump is 380V/3. The system is with thermal relay protection
which will automaticly disconnect when detecting
abnormalcurrent and voltage
,
the corresponding signal is I2B3.
Solution:
(
1
)
Please turn off the electricity to test the balance of
phase resistance.(2)Please check if the motor gets too much
hot.(3)Please check if the thermal relay is damaged or the
protecting current is too small
(
93.9A
)
.
E11
E11 Mold unlocked
The system is with the function of detecting mold locked
,
for
the safty to avoid collection accident. The corresponding
signal is I2B1 and present “ON” when the mold locked.
Solution:(1)Please check if the switch tuned to
locked.(2)Please check if the switch is damaged.(3)Please
check if the signal I2B1 is connected.
E12
E12 Communication
network alarm
The system is adoped EtherCat to alert when detecting fault.
Solution:(1)Please check the communication network
connection from touch screen to PLC.
(
2
)
Please check the
cable connection from PLC to drive in X axis and Y axis. Turn
off the power when alarming, and wait for 15s to restart the
power.If it still doesn’t work
,
please contact the equipment
developer.
E13
E13 Motion control
alarm
The system is with the detection the motion control alarm.
Solution: Turn off the power when alarming, and wait for 15s
to restart the power. If it still doesn’t work
,
please contact the
equipment developer.
E14
E14 PLC alarm
PLC can detection the faults.
Solution:(1)Please PLC alarm.(2)Please check if the
emergency button is pressed.(3)Please check the air pressure.
If it still alarms exclude the above references, please turn off
the power and wait for 15s to restart the power.
E15
E15 Bottom mould
pressing overtime
The system doesn’t detect the signal
(
I1A8
)
when pressing
bottom mould
at a predetermined time.
Solution: (1)Please check if the signal(I1A8) is “ON” when
pressing and the wire damaged.(2)Please check if the output
signal
(
O1A6
)
is” ON” and the wire damaged.(3) Please
check if the solenoid valve cables of O1A6 burned.
E16
E16 Bottom mould
lifting overtime
The system doesn’t detect the signal
(
I1A7
)
when lifting
bottom mould
at a predetermined time.
Solution: (1)Please check if the signal(I1A7) is “ON” and the
wire damaged.(2)Please check if the output signal
(
O1A5
)