6.2.2 Settings End User Level
Different settings can be changed in the end user level.
▶
Turn the dial knob.
✓
Tool bar appears.
▶
Turn the dial knob.
✓
Selection cursor alternates between the symbols.
▶
Press enter button.
✓
Set value will be shown flashing.
▶
Change the value with the dial knob.
▶
Save the value with the enter button.
Setting
Range
Factory setting
1
Normal supply temperature
setpoint
Setback flow temperature --- maximum flow tempera-
ture (P
31
)
---
= standby
60
°C
2
Setback supply temperature
setpoint
Minimum supply temperature (P
30
) … normal supply
temperature
30
°C
3
Type of operation
S
= Summer
W
= Winter
W
4
DHW setpoint value
30
°C …
65
°C
---
= DHW operation off
50
°C
5
Manual start up
chimney sweep function
minimum load ... maximum load
–
6
Heating Engineer Level
–
–
Installation and operating instruction
Gas condensing boiler WTC-GB 90-A