Installation and operating instructions
Communication module WCM-COM 1.0 home
5 Electrical installation
83279302 ▪ 2/2012-12 ▪ Mot
14-32
5.5
Network socket
The connection for the network cable is located on the right hand side of the housing and
is accessible externally.
▶
Open the bottom of the three covers on the side.
▶
Plug in network cable.
5.6
WCM-COM connection diagram
5.6.1
Mains voltage section
Terminal
Connection
Explanation
230 V
Supply voltage
230 V / 50 Hz
PE terminal
Protective conductor
-
5.6.2
Low voltage section
Terminal
Connection
Explanation
eBUS
Connect 2 pole eBUS cable,
observe polarity
Non power supplying eBUS
participant without Sync
Generator
“CAN“ connections are not taken into consideration with the WCM-COM.