1.3 Power Source Connections
Warning
Thermal Arc advises that this equipment be electrically connected by a qualified electrician.
ELECTRIC SHOCK can kill; SIGNIFICANT DC VOLTAGE is present after removal of
input power.
DO NOT TOUCH live electrical parts.
SHUT DOWN welding power source; disconnect input power employing lockout/tagging
procedures.
Lockout/tagging procedures consist of padlocking line disconnect switch in open position.
Removing fuses from fuse box, or shutting off and red-tagging circuit breaker or other
disconnecting device.
1.4
.
Power Supply Requirements
Input volt must be standard sine wave, effective value 230V±10%, and frequency 50/60Hz.
Unbalance degree of 1- phase volt must be no more than 5%.
Power supply:
Product type
FARC200
Power Supply
1- phase AC 230V±10%
,
50/60Hz
Electricity Grid
min. capacity
7.5KVA
Input volt
protection
Fuse
50A
Circuit Breaker
60A
Cable size
Input volt
2.5mm
2
Output volt
16mm
2
Ground lead
2.5mm
2
Table 2: FARC Series Power Supply Connection
Note: The size of fuse and breaker in the table are for reference only.