background image

 

 
 
 
 
 
 
 

 

Installation and Startup Guide

 

This document covers the installation of MT8073iE Series HMI, for the detailed specifications and 
operation, please refer to Brochure and EasyBuilder Pro User Manual. 

Install Environment: 

NEMA Rating

 

The 

HMI product is NEMA 4 rated (Indoor Only). 

 

Electrical 
Environment

 

The 

HMI product has been tested to conform to European CE requirements. This 

means that the circuitry is designed to resist the effects of electrical noise. This 
does not guarantee noise immunity in severe cases. Proper wire routing and 
grounding will insure proper operation.

 

Environmental 
Considerations

 

(1)  Make sure that the displays are installed correctly and that the operating 

limits are followed. Avoid installing units in environments where severe 
mechanical vibration or shocks are present. 

(2) 

The HMI product is certified in accordance with ATEX zone 2/22 categories 
3 G/D. The unit has to be installed in an additional enclosure ensuring a 
minimal protection level for 3G/D equipment. The enclosure equipped with 
the unit has to be certified and shouldn’t be opened when an explosive 
atmosphere is present.

 

(3)  Do not install the unit where acid gas, such as SO2 exists. 

(4) 

This device should be mounted in the vertical position and for use on the flat 
surface enclosure.

 

(5) 

Conform to UL508 (ISBN 0-7629-0404-6) machine safety for use in 
Pollution Degree 2 Environment.

 

 

Unpacking the Unit

 

Unpack and check the delivery. If damage is found,   
notify the supplier.   

Installation Instructions 

Secure the operator panel in position, using all the fastening holes and the provided brackets   
and screws. Screw Torque: 2.6 ~ 3.9 lbf.in. (For reaching waterproof effect and preventing the panel 
from being deformed.) 
 

 

 

 

Type 

A(mm) 

B(mm) 

MT8073iE 

192 

138 

 

USB Stick Clamp Usage 

Combining the USB Stick with the clamp and the tying strap can prevent USB stick from disconnecting 
with HMI when strong vibration is present. 
1. Insert the USB connector to the clamp and tie them together with the tying strap. 
2. Press the spring and insert the USB stick into HMI. 

 

 

Power Connections 

 

 

 

System Settings 

When HMI is powered up and displays image, press the 
system setting button in the lower-right corner of the screen. 
(Default System Password: 111111) 
Go to the Network tab, you may choose to auto get DHCP IP, or 
designate your own IP. 
MT8073iE has two10/100/1000 Base-T Ethernet ports. 
The default IP addresses are: 
LAN 1: DHCP 
LAN 2: 192.168.100.1 

MT8073iE series

 

                                                                                                               

Installation Instruction 

 

NOTE:   

Place the operator panel on a stable 
surface during installation. Dropping it or 
letting it fall may cause damage. 

 

NOTE:   

1. Conne

ct positive DC line to the ‘+’ terminal and the DC 

ground to the ‘-’ terminal. 
2. When using a USB cable to download project file, please 
do not connect HMI with PLC and PC simultaneously to 
prevent potential difference from destroying USB ports of 
HMI and PC. 

(A) 

(B) 

Cutout 

(1) 

 

(2) 

(3) 

 

(5)                        (4) 

(6)             

 

(1) Installation Instruction, 2-sided A4 *1 

(2) Human Machine Interface *1 

 

(3) Power Connector *1 

 

(4) Brackets & Screws *1 pack 

(5) USB Stick Clamp & Tying Strap *1

 

(6) Fuse 1.25A/250V 5*20mm *1

 