Part number 550-141-858/0107

2

WMZV

 

Zone Valve Controllers

The following defined terms are used throughout this manual to bring attention to the presence
of hazards of various risk levels or to important information concerning the life of the product.

Contents

Indicates presence of hazards that 

will cause

 severe personal injury, death

or substantial property damage.

Indicates presence of hazards that 

can cause

 severe personal injury, death

or substantial property damage.

Indicates presence of hazards that 

will or can cause

 

minor personal injury

or property damage.

Indicates special instructions on installation, operation or maintenance that
are important but not related to personal injury or property damage.

Electrical shock hazard — Disconnect power before installing or servicing.
Can cause severe personal injury, death or substantial property damage if
ignored.

All wiring must be installed in accordance with:

U.S.A.

 — National Electrical Code and any other national, state or local code

requirements. Wiring must be N.E.C. Class 1.

Canada

 — C.S.A. C22.1 Canadian Electrical Code Part 1 and any other

national, provincial or local code requirements. Wiring must be C.S.A.
C22.1 C.E.C. Part 1.

Replacement parts

Hazard definitions ............................................................ 2

Replacement parts ............................................................ 2

WMZV features ................................................................. 3

Wiring ............................................................................... 4

Hazard definitions

Please note:

Part description

Weil-McLain part number

Plug-in relay (24 VAC coil)

510-311-021

Field-mounted 40 VA transformer (used on WMZV-4 only)

511-842-370

Field-mounted 75 VA transformer (used on WMZV-6 only)

511-842-364

Содержание WMZV-4

Страница 1: ... 4 Four zone controller WMZV 6 Six zone controller This manual must only be used by a qualified heating installer service technician Failure to comply could result in severe personal injury death or substantial property damage Zone Valve Controllers ...

Страница 2: ...nt but not related to personal injury or property damage Electrical shock hazard Disconnect power before installing or servicing Can cause severe personal injury death or substantial property damage if ignored All wiring must be installed in accordance with U S A National Electrical Code and any other national state or local code requirements Wiring must be N E C Class 1 Canada C S A C22 1 Canadia...

Страница 3: ... zone valves including Taco Superior Erie Honeywell B G SPARCO and most other motorized and heat motor type valves 6 Switchable priority improves versatility 7 Plug in replaceable isolated contact relay 8 24 VAC constant power for 5 wire zone valves such as Honeywell VC Series 40 and 80 valves 9 Isolated end switch terminals X X 10 Powerful transformer 40 VA on WMZV 4 75 VA on WMZV 6 11 Galvanized...

Страница 4: ...RIORITY ZONE SWITCH is in the ON position the WMZV 4 will not activate zones 2 3 or 4 while the priority zone calls for heat All wiring must be installed in accordance with U S A National Electrical Code and any other national state or local code requirements Wiring must be N E C Class 1 Canada C S A C22 1 Canadian Electrical Code Part 1 and any other national provincial or local code requirements...

Отзывы: