  Failure to adhere to the guidelines on this page can result in severe personal 

injury, death or substantial property damage.

Boiler service and maintenance —

To avoid electric shock, disconnect all electrical supplies to the boiler before perform-

ing maintenance if wiring will be exposed.

To avoid severe burns, allow boiler to cool before performing maintenance.

You must maintain the boiler as outlined in this manual and 

have the boiler started 

up and serviced at least annually

 by a qualified service technician to ensure boiler/

system reliability.

Boiler operation —

Do not block flow of combustion or ventilation air to boiler. This boiler is equipped 

with a control which will automatically shut down the boiler should air or vent be 

blocked. If vent or air blockage is easily accessible and removable, remove it. If the 

boiler display indicates a manual reset lockout, follow the procedure in Figure 4, page 7 

to reset the boiler. (If blockage is not obvious or cannot be removed, have the boiler 

and system checked by a qualified service technician.)

Do not allow contaminated air to enter the boiler room (or air inlet pipe if direct 

vented). See page 8 for details.

Should overheating occur or gas supply fail to shut off, do not turn off or disconnect 

electrical supply to boiler. Instead, shut off the gas supply at a location external to 

the appliance.

Do not use this boiler if any part has been under water. Immediately call a qualified 

service technician to inspect the boiler and to replace any part of the control system 

and any gas control, which has been under water.

Boiler water —

Have boiler water chemistry checked at least annually by a qualified service technician.

DO NOT use petroleum-based cleaning or sealing compounds in boiler system. Gaskets 

and seals in the system may be damaged. This can result in substantial property damage.

DO NOT use “homemade cures” or “boiler patent medicines”. Serious damage to 

boiler, personnel and/or property may result.

Continual fresh makeup water will reduce boiler life. Mineral build-up in boiler heat 

exchanger reduces heat transfer, overheats the metal, and causes heat exchanger fail-

ure. Addition of oxygen can cause internal corrosion in system components. Leaks in 

boiler or piping must be repaired at once to prevent makeup water.

Do not add cold water to hot boiler. Thermal shock can cause boiler heat exchanger 

to crack.

STOP!  READ THIS BEFORE PROCEEDING . . .

Part number 550-100-088/0814

3

SlimFit

 

gas

-

fired

 

water

 

boiler

 — 

User’s Information Manual

Содержание SlimFit 550

Страница 1: ...F YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the...

Страница 2: ...gas supplier who must read and follow the supplied instructions before installing servicing or removing this boiler This boiler contains materials that have been identified as carcinogenic or possibly...

Страница 3: ...See page 8 for details Should overheating occur or gas supply fail to shut off do not turn off or disconnect electrical supply to boiler Instead shut off the gas supply at a location external to the a...

Страница 4: ...Figure 1 Operating instructions OPERATING INSTRUCTIONS Part number 550 100 088 0814 4 SlimFit gas fired water boiler User s Information Manual...

Страница 5: ...Figure 2 SlimFit component locations Boiler components Part number 550 100 088 0814 5 SlimFit gas fired water boiler User s Information Manual...

Страница 6: ...Figure 3 SlimFit boiler s U Control display The U Control display Part number 550 100 088 0814 6 SlimFit gas fired water boiler User s Information Manual...

Страница 7: ...creen SETTINGS will be highlighted Press the DOWN arrow to move down to MANUAL RESET Press ENTER center button The display will switch to the manual reset screen indicating what caused the shutdown Pr...

Страница 8: ...low If contaminating chemicals will be present near the location of the boiler combustion air inlet have your installer pipe the boiler combustion air and vent to another location per the Boiler manua...

Страница 9: ...lve Check condensate drain system Check automatic air vents if used PERIODICALLY Test low water cutoff Check time and date on the U Control display EVERY 6 MONTHS Check boiler piping gas and water Ope...

Страница 10: ...aintenance and care of the boiler listed on Figure 5 page 9 and explained in this manual must be performed to assure maximum boiler efficiency and reliability Failure to service and maintain the boile...

Страница 11: ...to the boiler from outside a Visually inspect all combustion air openings b Remove any debris or blockage from combustion air louvers The combustion air openings must be unobstructed This is the mean...

Страница 12: ...4 for procedure to fill trap Call your qualified service technician to inspect the boiler and condensate line and refill the condensate trap if problem persists regularly Under some circumstances an S...

Страница 13: ...Control display will flash red as shown in Figure 4 page 7 7 Select MANUAL RESET to reset the control 8 The boiler should return to normal operation If the low water cutoff fails to cause a manual res...

Страница 14: ...to valve operation a metal discharge line must be connected to relief valve outlet and run to a safe place of disposal This discharge line must be installed by a qualified heating installer or servic...

Страница 15: ...ol as needed to operate the necessary circulators 2 Leave the boiler power on and allow the U Control to monitor the boiler and system dur ing the stand by period The U Control must be configured to o...

Страница 16: ...Part number 550 100 088 0814 16 SlimFit gas fired water boiler User s Information Manual...

Отзывы: