2.1.3
Clear the Drive Alarm
To clear the drive alarm, do the following:
1.
Check if the wiring of the drive is connected correctly and securely:
–
If it is, proceed to the next step.
–
If it is not, correct and tighten the wiring.
2.
Check if the setting value of parameter
Drive Station Address
is the same as
the drive station address of the machine tool:
–
If it is, proceed to the next step.
–
If it is not, modify the setting value of the parameter according to the
drive station address of the machine tool.
3.
Check if the polarity of port
Servo Alarm
is in
NC
status:
If it is not, modify the port polarity to
NC
status.
2.2
Set Drive Parameters
This operation is used to set drive parameters via the software after the system is
well connected to the servo drive.
Before setting drive parameters, ensure the system has been connected to the
hardware correctly.
To set drive parameters, do the following:
1.
Click
System
→
Drive Param
.
Drive Param
dialog box pops up: