background image

TARE

ZERO

HOLD

UNIT

OFF

ON

 

FUNCTION KEYS 

UNIT

TARE

NET

HOLD

ZERO

OFF

ON

HOLD

 

Description: 

Tare

 

- Set the display to zero by storing the 
current weight in the tare memory 

 
 

    On / Zero / Off

  

- Turns the scale on, zero or off, 

Units 

 

 

 

- Select kilograms, pounds or ounces 

 

   

Hold           

 

 

- Temporarily memory the weight. 

Place an item to be weighed on the 
platform. Press HOLD key, the arrow of 
the left bottom will blink. The display 
shows the measured weight. 

                                                  After removing the item, the display still 

shows the weight. 

 

Press HOLD or TARE button to disable 
HOLD function. 

Turn the scale on using the 

On/Zero/Off

 key.    After the display is at 

zero, place an item to be weighed on the platform.    The display will 
show the weight.    The unit will be shown in kilograms unless the user 
has selected either pounds or ounces previously. 
If an empty container is used the weight can be ignored by zeroing the 

display.    To zero the display press the 

TARE

 key.    Then when material 

is placed in the container only the weight of the material will be shown. 

3. Insert the male plug into the stainless steel 

stick, which will be screwed into the hole 
between the two sides of holes of platform.  
See figure 3

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3

 

 

 

 

Male plug 

Содержание MS-2500

Страница 1: ...tured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 89 336 EEC Low Voltage Directive 73 23 EEC Marsden Group Holding Ltd WM 25 TARE ZERO HOLD UNIT OFF ON USER S MANUAL ...

Страница 2: ... DC adaptor for operations and recharge DC ADAPTOR OPERATION Note Always fit the Adaptor to the scale BEFORE connecting to an electrical outlet Disconnect from the electrical outlet BEFORE disconnecting the adaptor from the scale SPECIFICATIONS Model MS 2500 Maximum Capacity 300 kg 660 lb Separation division 100 g 0 2 lb Weight unit Kg Lb oz Power Supply Rechargeable battery pack 15V 300mA DC adap...

Страница 3: ...ght Press HOLD or TARE button to disable HOLD function Turn the scale on using the On Zero Off key After the display is at zero place an item to be weighed on the platform The display will show the weight The unit will be shown in kilograms unless the user has selected either pounds or ounces previously If an empty container is used the weight can be ignored by zeroing the display To zero the disp...

Страница 4: ...7 ...

Страница 5: ...e capacity Tare the scale place the mass on the center of the platform and note the reading Calibrate the scale if necessary Before beginning make sure you have the mass specified and you know the mass is accurate PROCEDURE Turn the scale off Press and hold the On Zero Off key then press the Units key 3 times Release the ON Zero OFF key The display will show the gravity value of the factory 9 789 ...

Страница 6: ...ng unit can be enabled or disabled 4 The Automatic Turn off time can be set or disabled off Each BMI can be enabled or disabled 5 SEt kg Lb Oz Unit 120 180 240 300 Off A Off On Off On Off St On Off On Off Unit A off CAP CAL DIV GRAV BMI On Off The other functions do not apply to the users Advance to END in order to exit the menu If you need use BMI be sure that you set BMI on and go to END first P...

Страница 7: ...e sticks Put the middle bar of indicator head into the stick which between the two sides of sticks firstly And then put the other two bars into the sticks separately See figure 4 The fabricating is completed See figure 5 TARE ZERO HOLD UNIT OFF ON Figure 5 ...

Страница 8: ......